T1 - Two-Point Frequency Shift Method for Shear Wave Attenuation Measurement
AU - Kijanka, Piotr
AU - Urban, Matthew W.
N1 - Funding Information:
Manuscript received May 14, 2019; accepted October 1, 2019. Date of publication October 4, 2019; date of current version February 25, 2020. This work was supported by the National Institutes of Health under Grant R01DK092255. (Corresponding authors: Piotr Kijanka; Matthew W. Urban.) P. Kijanka is with the Department of Radiology, Mayo Clinic, Rochester, MN 55905 USA, and also with the Department of Robotics and Mechatronics, AGH University of Science and Technology, 30-059 Kraków, Poland (e-mail: piotr.kijanka. . edu.pl).
Publisher Copyright:
© 1986-2012 IEEE.
PY - 2020/3/1
Y1 - 2020/3/1
N2 - Ultrasound shear wave elastography (SWE) is an increasingly used noninvasive modality for quantitative evaluation of tissue mechanical properties. SWE typically uses an acoustic radiation force to produce laterally propagating shear waves that are tracked in the spatial and temporal domains, in order to obtain the wave velocity. One of the ways to study the viscoelasticity is through studying the shear wave phase velocity dispersion curves. Shear wave attenuation can be also characterized in viscoelastic tissues with methods that use multiple lateral data samples. In this article, we present an alternative method for measuring the shear wave attenuation without using a rheological model two-point frequency shift (2P-FS). The technique uses information related to the amplitude spectra FS of shear waves measured at only two lateral locations. The theoretical basis for the 2P-FS is derived and validated. We examined how the first signal position and the distance between the two locations affect the shear wave attenuation estimation in the 2P-FS method. We tested this new method on digital phantom data created using the local interaction simulation approach (LISA) in viscoelastic media. Moreover, we tested data acquired from custom-made tissue-mimicking viscoelastic phantom experiments and ex vivo porcine liver measurements. We compared results from the 2P-FS method with the other two techniques used for assessing a shear wave attenuation: the FS-based method and the attenuation-measuring ultrasound shear wave elastography (AMUSE) technique. In addition, we evaluated the 2P-FS algorithm with different levels of added white Gaussian noise to the shear wave particle velocity using numerical phantoms. Tests conducted showed that the 2P-FS method gives robust results based on only two measurements and can be used to measure attenuation of viscoelastic soft tissues.
AB - Ultrasound shear wave elastography (SWE) is an increasingly used noninvasive modality for quantitative evaluation of tissue mechanical properties. SWE typically uses an acoustic radiation force to produce laterally propagating shear waves that are tracked in the spatial and temporal domains, in order to obtain the wave velocity. One of the ways to study the viscoelasticity is through studying the shear wave phase velocity dispersion curves. Shear wave attenuation can be also characterized in viscoelastic tissues with methods that use multiple lateral data samples. In this article, we present an alternative method for measuring the shear wave attenuation without using a rheological model two-point frequency shift (2P-FS). The technique uses information related to the amplitude spectra FS of shear waves measured at only two lateral locations. The theoretical basis for the 2P-FS is derived and validated. We examined how the first signal position and the distance between the two locations affect the shear wave attenuation estimation in the 2P-FS method. We tested this new method on digital phantom data created using the local interaction simulation approach (LISA) in viscoelastic media. Moreover, we tested data acquired from custom-made tissue-mimicking viscoelastic phantom experiments and ex vivo porcine liver measurements. We compared results from the 2P-FS method with the other two techniques used for assessing a shear wave attenuation: the FS-based method and the attenuation-measuring ultrasound shear wave elastography (AMUSE) technique. In addition, we evaluated the 2P-FS algorithm with different levels of added white Gaussian noise to the shear wave particle velocity using numerical phantoms. Tests conducted showed that the 2P-FS method gives robust results based on only two measurements and can be used to measure attenuation of viscoelastic soft tissues.
KW - Acoustic radiation force (ARF)
KW - attenuation
KW - attenuation measuring ultrasound shear wave elastography (AMUSE)
KW - frequency shift (FS)
KW - full-width at half-maximum (FWHM)
KW - phantom
KW - shear wave elastography (SWE)
KW - soft tissue
KW - ultrasound
KW - viscoelastic
UR - http://www.scopus.com/inward/record.url?scp=85080955226&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85080955226&partnerID=8YFLogxK
U2 - 10.1109/TUFFC.2019.2945620
DO - 10.1109/TUFFC.2019.2945620
M3 - Article
C2 - 31603777
AN - SCOPUS:85080955226
SN - 0885-3010
VL - 67
SP - 483
EP - 496
JO - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
JF - IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
IS - 3
M1 - 8859337
ER -