T1 - Tube dysfunction following percutaneous endoscopic gastrostomy and jejunostomy
AU - Wolfsen, H. C.
AU - Kozarek, R. A.
AU - Ball, T. J.
AU - Patterson, D. J.
AU - Botoman, V. A.
PY - 1990
Y1 - 1990
N2 - Percutaneous endoscopic gastrostomy (PEG) and jejunostomy (PEJ) have supplanted their surgical counterparts in many institutions. Previous reports have claimed advantages in placing PEJ tubes because of reduced gastroesophageal reflux, prevention of aspiration, and improved tube anchoring distally. We reviewed the records of 191 patients who underwent placement of PEG/J tubes. Data collected included incidence of tube dysfunction, need for tube replacement or removal, and aspiration after PEG or PEJ tube placement. Tube dysfunction, defined as peritube leakage, plugging, fracture, or migration, occurred in 36% of patients over a mean follow-up period of 275 days and was significantly more common and likely to necessitate tube replacement in PEJ patients. Tube trade-out or removal and aspiration within a 30-day period after tube placement occurred in 28% and 10% of patients, respectively. These complications were significantly more common in PEJ patients than in PEG patients. Because of the increased incidence of tube dysfunction and the failure to prevent aspiration in predisposed patients, PEJ tube placement is not routinely indicated in patients requiring tube feedings.
AB - Percutaneous endoscopic gastrostomy (PEG) and jejunostomy (PEJ) have supplanted their surgical counterparts in many institutions. Previous reports have claimed advantages in placing PEJ tubes because of reduced gastroesophageal reflux, prevention of aspiration, and improved tube anchoring distally. We reviewed the records of 191 patients who underwent placement of PEG/J tubes. Data collected included incidence of tube dysfunction, need for tube replacement or removal, and aspiration after PEG or PEJ tube placement. Tube dysfunction, defined as peritube leakage, plugging, fracture, or migration, occurred in 36% of patients over a mean follow-up period of 275 days and was significantly more common and likely to necessitate tube replacement in PEJ patients. Tube trade-out or removal and aspiration within a 30-day period after tube placement occurred in 28% and 10% of patients, respectively. These complications were significantly more common in PEJ patients than in PEG patients. Because of the increased incidence of tube dysfunction and the failure to prevent aspiration in predisposed patients, PEJ tube placement is not routinely indicated in patients requiring tube feedings.
UR - http://www.scopus.com/inward/record.url?scp=0025300619&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025300619&partnerID=8YFLogxK
U2 - 10.1016/S0016-5107(90)71019-X
DO - 10.1016/S0016-5107(90)71019-X
M3 - Article
C2 - 2114339
AN - SCOPUS:0025300619
SN - 0016-5107
VL - 36
SP - 261
EP - 263
JO - Gastrointestinal endoscopy
JF - Gastrointestinal endoscopy
IS - 3
ER -