Technical Note: Insertion of digital lesions in the projection domain for dual-source, dual-energy CT

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Purpose: To compare algorithms performing material decomposition and classification in dual-energy CT, it is desirable to know the ground truth of the lesion to be analyzed in real patient data. In this work, we developed and validated a framework to insert digital lesions of arbitrary chemical composition into patient projection data acquired on a dual-source, dual-energy CT system. Methods: A model that takes into account beam-hardening effects was developed to predict the CT number of objects with known chemical composition. The model utilizes information about the x-ray energy spectra, the patient/phantom attenuation, and the x-ray detector energy response. The beam-hardening model was validated on samples of iodine (I) and calcium (Ca) for a second-generation dual-source, dual-energy CT scanner for all tube potentials available and a wide range of patient sizes. The seven most prevalent mineral components of renal stones were modeled and digital stones were created with CT numbers computed for each patient/phantom size and x-ray energy spectra using the developed beam-hardening model. Each digital stone was inserted in the dual-energy projection data of a water phantom scanned on a dual-source scanner and reconstructed with the routine algorithms in use in our practice. The geometry of the forward projection for dual-energy data was validated by comparing CT number accuracy and high-contrast resolution of simulated dual-energy CT data of the ACR phantom with experimentally acquired data. Results: The beam-hardening model and forward projection method accurately predicted the CT number of I and Ca over a wide range of tube potentials and phantom sizes. The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner, and the CT number ratios for different kidney stone types were consistent with data in the lit-erature. A sample application of the proposed tool was also demonstrated. Conclusion: A framework was developed and validated for the creation of digital objects of known mineral composition, and for inserting the digital objects into projection data from a commercial dual-source, dual-energy CT scanner. Among other applications, it will allow a systematic investigation of the impact of scan and reconstruction parameters on kidney stone dual-energy properties under rigorously controlled conditions.

Original languageEnglish (US)
Pages (from-to)1655-1660
Number of pages6
JournalMedical physics
Volume44
Issue number5
DOIs
StatePublished - May 2017

Keywords

  • computed tomography (CT)
  • dual-energy CT
  • lesion insertion
  • material decomposition
  • projection domain

ASJC Scopus subject areas

  • Biophysics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Technical Note: Insertion of digital lesions in the projection domain for dual-source, dual-energy CT'. Together they form a unique fingerprint.

Cite this