T1 - Slow phase of transvascular fluid flux reviewed
AU - Hancock, B. J.
AU - Landolfo, K. P.
AU - Hoppensack, M.
AU - Oppenheimer, L.
PY - 1990/1/1
Y1 - 1990/1/1
N2 - In six circuit experiments using a clinical hemofiltration device, we validated a colorimetric technique to measure transvascular volume exchange (V(E)). In 12 isolated excised canine left lower lobes, continuous colorimetric measures of V(E) correlated well with calculations of V(E) from changes in microhematocrit obtained simultaneously. We introduced step increases in microvascular hydrostatic pressure (Pc) of 9 ± 4.8 (SD) cmH2O and followed the time course of weight and continuous hematocrit changes measured colorimetrically for 40 min, after which Pc was returned to base line, while measurements were continuously obtained. This procedure was repeated for an additional 30 min. V(E) was calculated from the hematocrit signals and compared with the time course of the weight signal. After increases in Pc, followed by a rapid weight gain, weight signals followed a slow exponential time course, whereas the calculated V(E) changed linearly. V(E) reflected ~60% of the slow weight gain. When P(c) was decreased, weight signals decreased exponentially, whereas V(E) continued to increase linearly at a slower rate. These results suggest that a significant component of the slow weight signal represents slow vascular volume changes. Contrary to what the weight signal suggested, edema was never reabsorbed over the range of Pc measured.
AB - In six circuit experiments using a clinical hemofiltration device, we validated a colorimetric technique to measure transvascular volume exchange (V(E)). In 12 isolated excised canine left lower lobes, continuous colorimetric measures of V(E) correlated well with calculations of V(E) from changes in microhematocrit obtained simultaneously. We introduced step increases in microvascular hydrostatic pressure (Pc) of 9 ± 4.8 (SD) cmH2O and followed the time course of weight and continuous hematocrit changes measured colorimetrically for 40 min, after which Pc was returned to base line, while measurements were continuously obtained. This procedure was repeated for an additional 30 min. V(E) was calculated from the hematocrit signals and compared with the time course of the weight signal. After increases in Pc, followed by a rapid weight gain, weight signals followed a slow exponential time course, whereas the calculated V(E) changed linearly. V(E) reflected ~60% of the slow weight gain. When P(c) was decreased, weight signals decreased exponentially, whereas V(E) continued to increase linearly at a slower rate. These results suggest that a significant component of the slow weight signal represents slow vascular volume changes. Contrary to what the weight signal suggested, edema was never reabsorbed over the range of Pc measured.
KW - filtration coefficient
KW - hematocrit
UR - http://www.scopus.com/inward/record.url?scp=0025121531&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0025121531&partnerID=8YFLogxK
U2 - 10.1152/jappl.1990.69.2.456
DO - 10.1152/jappl.1990.69.2.456
M3 - Article
C2 - 2228855
AN - SCOPUS:0025121531
SN - 0161-7567
VL - 69
SP - 456
EP - 464
JO - Journal of applied physiology
JF - Journal of applied physiology
IS - 2
ER -