T1 - Reproducibility of 3D micro-CT gray-scale and structural dimension data in longitudinal studies
AU - Jorgensen, Steven M.
AU - Eaker, Diane R.
AU - Vercnocke, Andrew J.
AU - Ritman, Erik L.
PY - 2006
Y1 - 2006
N2 - Repeated micro-CT scanning of a number of iliac crest biopsies enabled us to quantitate the variation in CT image gray-scale and spatial geometry due to variables such as specimen orientation, projection magnification, voxel size and slight differences in x-ray photon energy in each of the different scans. Using the micro-CT scanner on beamline X2B at the Brookhaven National Laboratory's National Synchrotron Light Source, we rescanned several iliac crest bone biopsy specimens, and a test phantom made of calcium hydroxyapatite, at repeated scanning sessions and evaluated the reproducibility of the spatial geometry and gray-scale characteristics of the specimens. This scanner consists of a Bragg diffraction source of monochromatic x-rays, a computer controlled high precision specimen rotation and translation stage assembly, and a fluorescent crystal and CCD array system for imaging the specimen at each of the angles of view around its axis of rotation during the scanning sequence. The 3-D micro-CT images consisted of up to 1024×24002, 4 μm, cubic voxels, each with 16-bit gray-scale. We also reconstructed the images at 16, 32 and 48 μm voxel resolution. Partial volume effects at the surface of the bone were diminished by 'eroding' the surface voxels in the 4 μm images, but significantly changed the outcome at greater voxel size. Reproducibility of the mineral content of bone, at mean bone opacity value, was ± 28.8 mg/cm3, i.e., 2.56%, in a 4 μm cubic voxel at the 95% confidence level.
AB - Repeated micro-CT scanning of a number of iliac crest biopsies enabled us to quantitate the variation in CT image gray-scale and spatial geometry due to variables such as specimen orientation, projection magnification, voxel size and slight differences in x-ray photon energy in each of the different scans. Using the micro-CT scanner on beamline X2B at the Brookhaven National Laboratory's National Synchrotron Light Source, we rescanned several iliac crest bone biopsy specimens, and a test phantom made of calcium hydroxyapatite, at repeated scanning sessions and evaluated the reproducibility of the spatial geometry and gray-scale characteristics of the specimens. This scanner consists of a Bragg diffraction source of monochromatic x-rays, a computer controlled high precision specimen rotation and translation stage assembly, and a fluorescent crystal and CCD array system for imaging the specimen at each of the angles of view around its axis of rotation during the scanning sequence. The 3-D micro-CT images consisted of up to 1024×24002, 4 μm, cubic voxels, each with 16-bit gray-scale. We also reconstructed the images at 16, 32 and 48 μm voxel resolution. Partial volume effects at the surface of the bone were diminished by 'eroding' the surface voxels in the 4 μm images, but significantly changed the outcome at greater voxel size. Reproducibility of the mineral content of bone, at mean bone opacity value, was ± 28.8 mg/cm3, i.e., 2.56%, in a 4 μm cubic voxel at the 95% confidence level.
KW - Bone
KW - Interpolation
KW - Mineralization
KW - Partial volume effects
KW - Photon energy bandwidth
KW - Voxel size
KW - X-ray synchrotron
UR - http://www.scopus.com/inward/record.url?scp=33745369890&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33745369890&partnerID=8YFLogxK
U2 - 10.1117/12.654436
DO - 10.1117/12.654436
M3 - Conference contribution
AN - SCOPUS:33745369890
SN - 0819461865
SN - 9780819461865
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2006
T2 - Medical Imaging 2006: Physiology, Function, and Structure from Medical Images
Y2 - 12 February 2006 through 14 February 2006
ER -