T1 - Reflectance spectrophotometry in the gastrointestinal tract
T2 - Limitations and new applications
AU - Ramirez, Francisco C.
AU - Padda, Sukhdeep
AU - Medlin, Susan
AU - Tarbeil, Helen
AU - Leung, Felix W.
N1 - Funding Information:
Supported in part by the American Society for Gastrointestinal Endoscopy and American Digestive Health Foundation: Olympus Endoscopic Career Development Award (F.C.R.), and the Veteran Affairs Medical Research Funds (F.W.L.).
PY - 2002/11/1
Y1 - 2002/11/1
N2 - OBJECTIVES: Reflectance spectrophotometry (RS) assesses blood flow changes by measuring an index of Hb concentration (IHB) and index of Hb oxygen saturation (ISO2). We tested the following hypotheses: 1) endoscopic RS measurements obtained by two observers and with the aid of fiber optic and video endoscopes are similar, and 2) the method is suitable for documenting mesenteric venoconstriction associated with systemic hypoxia and blood flow autoregulation associated with hemorrhagic hypotension. METHODS: Study 1: two investigators obtained baseline gastric mucosal RS measurements in anesthetized rats (n = 3) before and after stepwise reduction of blood pressure induced by arterial hemorrhage. Study 2: subjects were examined by both fiber optic and video endoscopes. Endoscopic RS measurements were obtained at 20 cm from the anal verge. Study 3: video endoscope was used to obtain RS measurements in oxygen-dependent patients on and off oxygen treatment. Study 4: the procedures in study 1 were repeated in five additional rats by one of the investigators. RESULTS: Study 1: there was good agreement between the measurements of IHB and ISO2 between the two investigators. Study 2: video endoscope-assisted measurements were consistently lower. Study 3: cessation of oxygen treatment produced a significant drop in oxygen saturation (pulse oximetry), decline in ISO2, and rise in IHB. Study 4: when blood pressure varied between 90% and 40% of baseline, gastric mucosal blood flow (IHB) was maintained at -70% of baseline level. CONCLUSIONS: We confirmed that reproducible measurement can be obtained by different investigators using standardized techniques. Standardization of endoscopic equipment is also necessary to overcome the significant limitation of endoscopic equipment on RS measurements. RS measurements can document mesenteric venoconstriction associated with systemic hypoxia and blood flow autoregulation associated with hemorrhagic hypotension.
AB - OBJECTIVES: Reflectance spectrophotometry (RS) assesses blood flow changes by measuring an index of Hb concentration (IHB) and index of Hb oxygen saturation (ISO2). We tested the following hypotheses: 1) endoscopic RS measurements obtained by two observers and with the aid of fiber optic and video endoscopes are similar, and 2) the method is suitable for documenting mesenteric venoconstriction associated with systemic hypoxia and blood flow autoregulation associated with hemorrhagic hypotension. METHODS: Study 1: two investigators obtained baseline gastric mucosal RS measurements in anesthetized rats (n = 3) before and after stepwise reduction of blood pressure induced by arterial hemorrhage. Study 2: subjects were examined by both fiber optic and video endoscopes. Endoscopic RS measurements were obtained at 20 cm from the anal verge. Study 3: video endoscope was used to obtain RS measurements in oxygen-dependent patients on and off oxygen treatment. Study 4: the procedures in study 1 were repeated in five additional rats by one of the investigators. RESULTS: Study 1: there was good agreement between the measurements of IHB and ISO2 between the two investigators. Study 2: video endoscope-assisted measurements were consistently lower. Study 3: cessation of oxygen treatment produced a significant drop in oxygen saturation (pulse oximetry), decline in ISO2, and rise in IHB. Study 4: when blood pressure varied between 90% and 40% of baseline, gastric mucosal blood flow (IHB) was maintained at -70% of baseline level. CONCLUSIONS: We confirmed that reproducible measurement can be obtained by different investigators using standardized techniques. Standardization of endoscopic equipment is also necessary to overcome the significant limitation of endoscopic equipment on RS measurements. RS measurements can document mesenteric venoconstriction associated with systemic hypoxia and blood flow autoregulation associated with hemorrhagic hypotension.
UR - http://www.scopus.com/inward/record.url?scp=0036841765&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036841765&partnerID=8YFLogxK
U2 - 10.1111/j.1572-0241.2002.07022.x
DO - 10.1111/j.1572-0241.2002.07022.x
M3 - Article
C2 - 12425548
AN - SCOPUS:0036841765
SN - 0002-9270
VL - 97
SP - 2780
EP - 2784
JO - American Journal of Gastroenterology
JF - American Journal of Gastroenterology
IS - 11
ER -