TY - JOUR
T1 - Pulmonary Capillary Recruitment Is Attenuated Post Left Ventricular Assist Device Implantation
AU - Kim, Chul Ho
AU - Sajgalik, Pavol
AU - Schettle, Sarah D.
AU - Clavell, Alfredo L.
AU - Stulak, John M.
AU - Taylor, Bryan J.
AU - Johnson, Bruce D.
N1 - Publisher Copyright:
© 2023 Elsevier Inc.
PY - 2023/7/15
Y1 - 2023/7/15
N2 - There is limited knowledge of pulmonary physiology and pulmonary function after continuous flow-left ventricular assist device (CF-LVAD) implantation. Therefore, this study investigated whether CF-LVAD influenced pulmonary circulation by assessing pulmonary capillary blood volume and alveolar-capillary conductance in addition to pulmonary function in patients with heart failure. Seventeen patients with severe heart failure who were scheduled for CF-LVAD implantation (HeartMate II, III, Abbott, Abbott Park, IL or Heart Ware, Medtronic, Minneapolis, MN) participated in the study. They underwent pulmonary function testing (measures of lung volumes and flow rates) and unique measures of pulmonary physiology using a rebreathe technique that quantified the diffusing capacity of the lungs for carbon monoxide (DLCO) and diffusing capacity of the lungs for nitric oxide before and 3 months after CF-LVAD implantation. After CF-LVAD, pulmonary function was not significantly changed (p >0.05). For lung diffusing capacity, alveolar volume (VA) was not changed (p = 0.47), but DLCO was significantly reduced (p = 0.04). After correcting for VA, DLCO/VA showed a trend toward reduction (p = 0.08). For the alveolar-capillary component, capillary blood volume (Vc) was significantly reduced (p = 0.04), and alveolar-capillary membrane conductance trended toward a reduction (p = 0.06). However, alveolar-capillary membrane conductance/Vc was not altered (p = 0.92). In conclusion, soon after CF-LVAD implantation, Vc is reduced likely because of pulmonary capillary derecruitment, which contributes to the decrease in lung diffusing capacity.
AB - There is limited knowledge of pulmonary physiology and pulmonary function after continuous flow-left ventricular assist device (CF-LVAD) implantation. Therefore, this study investigated whether CF-LVAD influenced pulmonary circulation by assessing pulmonary capillary blood volume and alveolar-capillary conductance in addition to pulmonary function in patients with heart failure. Seventeen patients with severe heart failure who were scheduled for CF-LVAD implantation (HeartMate II, III, Abbott, Abbott Park, IL or Heart Ware, Medtronic, Minneapolis, MN) participated in the study. They underwent pulmonary function testing (measures of lung volumes and flow rates) and unique measures of pulmonary physiology using a rebreathe technique that quantified the diffusing capacity of the lungs for carbon monoxide (DLCO) and diffusing capacity of the lungs for nitric oxide before and 3 months after CF-LVAD implantation. After CF-LVAD, pulmonary function was not significantly changed (p >0.05). For lung diffusing capacity, alveolar volume (VA) was not changed (p = 0.47), but DLCO was significantly reduced (p = 0.04). After correcting for VA, DLCO/VA showed a trend toward reduction (p = 0.08). For the alveolar-capillary component, capillary blood volume (Vc) was significantly reduced (p = 0.04), and alveolar-capillary membrane conductance trended toward a reduction (p = 0.06). However, alveolar-capillary membrane conductance/Vc was not altered (p = 0.92). In conclusion, soon after CF-LVAD implantation, Vc is reduced likely because of pulmonary capillary derecruitment, which contributes to the decrease in lung diffusing capacity.
UR - http://www.scopus.com/inward/record.url?scp=85160255128&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85160255128&partnerID=8YFLogxK
U2 - 10.1016/j.amjcard.2023.05.001
DO - 10.1016/j.amjcard.2023.05.001
M3 - Article
C2 - 37245249
AN - SCOPUS:85160255128
SN - 0002-9149
VL - 199
SP - 44
EP - 49
JO - American Journal of Cardiology
JF - American Journal of Cardiology
ER -