Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices

Troy J. Cross, Pavol Sajgalik, Vratislav Fabian, Lukas Matera, Sudhir S. Kushwaha, Simon Maltais, John M. Stulak, John A. Schirger, Bruce D. Johnson

Research output: Contribution to journalArticlepeer-review

Abstract

Introduction: Long-term use of continuous-flow left ventricular assist devices may have negative consequences for autonomic, cardiovascular and gastrointestinal function. It has thus been suggested that non-invasive monitoring of arterial pulsatility in patients with a left ventricular assist device is highly important for ensuring patient safety and longevity. We have developed a novel, semi-automated frequency-domain-based index of arterial pulsatility that is obtained during suprasystolic occlusions of the upper arm: the ‘cuff pulsatility index’. Purpose: The purpose of this study was to evaluate the relationship between the cuff pulsatility index and invasively determined arterial pulsatility in patients with a left ventricular assist device. Methods: Twenty-three patients with a left ventricular assist device with end-stage heart failure (six females: age = 65 ± 9 years; body mass index = 30.5 ± 3.7 kg m−2) were recruited for this study. Suprasystolic occlusions were performed on the upper arm of the patient’s dominant side, from which the cuff pressure waveform was obtained. Arterial blood pressure was obtained from the radial artery on the contralateral arm. Measurements were obtained in triplicate. The relationship between the cuff pressure and arterial blood pressure waveforms was assessed in the frequency-domain using coherence analysis. A mixed-effects approach was used to assess the relationship between cuff pulsatility index and invasively determined arterial pulsatility (i.e. pulse pressure). Results: The cuff pressure and arterial blood pressure waveforms demonstrated a high coherence up to the fifth harmonic of the cardiac frequency (heart rate). The cuff pulsatility index accurately tracked changes in arterial pulse pressure within a given patient across repeated measurements. Conclusions: The cuff pulsatility index shows promise as a non-invasive index for monitoring residual arterial pulsatility in patients with a left ventricular assist device across time.

Original languageEnglish (US)
Pages (from-to)99-108
Number of pages10
JournalInternational Journal of Artificial Organs
Volume43
Issue number2
DOIs
StatePublished - Feb 1 2020

Keywords

  • Left ventricular assist device
  • non-invasive
  • pulsatility index

ASJC Scopus subject areas

  • Medicine (miscellaneous)
  • Bioengineering
  • Biomaterials
  • Biomedical Engineering

Fingerprint

Dive into the research topics of 'Non-invasive assessment of arterial pulsatility in patients with continuous-flow left ventricular assist devices'. Together they form a unique fingerprint.

Cite this