Initial multicenter experience using a novel endoscopic tack and suture system for challenging GI defect closure and stent fixation (with video)

Tala Mahmoud, Louis M. Wong Kee Song, Stavros N. Stavropoulos, Tarek H. Alansari, Hemchand Ramberan, Norio Fukami, Neil B. Marya, Prashanth Rau, Christopher Marshall, Bachir Ghandour, Michael Bejjani, Mouen A. Khashab, Gregory B. Haber, Hiroyuki Aihara, Mainor R. Antillon-Galdamez, Vinay Chandrasekhara, Barham K. Abu Dayyeh, Andrew C. Storm

Research output: Contribution to journalArticlepeer-review

Abstract

Background and Aims: Closure of endoscopic resection defects can be achieved with through-the-scope clips, over-the-scope clips, or endoscopic suturing. However, these devices are often limited by their inability to close large, irregular, and difficult-to-reach defects. Thus, we aimed to assess the feasibility and safety of a novel through-the-scope, suture-based closure system developed to overcome these limitations. Methods: This was a retrospective multicenter study involving 8 centers in the United States. Primary outcomes were feasibility and safety of early use of the device. Secondary outcomes were assessment of need for additional closure devices, prolonged procedure time, and technical feasibility of performing the procedure with an alternative device(s). Results: Ninety-three patients (48.4% women) with mean age 63.6 ± 13.1 years were included. Technical success was achieved in 83 patients (89.2%), and supplemental closure was required in 24.7% of patients (n = 23) with a mean defect size of 41.6 ± 19.4 mm. Closure with an alternative device was determined to be impossible in 24.7% of patients because of location, size, or shape of the defect. The use of the tack and suture device prolonged the procedure in 8.6% of cases but was considered acceptable. Adverse events occurred in 2 patients (2.2%) over a duration of follow-up of 34 days (interquartile range, 13-93.5) and were mild and moderate in severity. No serious adverse events or procedure-related deaths occurred. Conclusions: The novel endoscopic through-the-scope tack and suture system is safe, efficient, and permits closure of large and irregularly shaped defects that were not possible with established devices.

Original languageEnglish (US)
Pages (from-to)373-382
Number of pages10
JournalGastrointestinal endoscopy
Volume95
Issue number2
DOIs
StatePublished - Feb 2022

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Gastroenterology

Fingerprint

Dive into the research topics of 'Initial multicenter experience using a novel endoscopic tack and suture system for challenging GI defect closure and stent fixation (with video)'. Together they form a unique fingerprint.

Cite this