TY - JOUR
T1 - High resolution diffusion tensor imaging of human nerves in forearm
AU - Zhou, Yuxiang
AU - Narayana, Ponnada A.
AU - Kumaravel, Manickam
AU - Athar, Parveen
AU - Patel, Vipulkumar S.
AU - Sheikh, Kazim A.
PY - 2014/6
Y1 - 2014/6
N2 - Purpose To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm. Materials and Methods This HIPAA-compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T1-and T 2-weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0×1.0×3.0 mm3) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ//) and radial diffusivity (λ⊥) were generated. Results For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI-derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI-derived measures, FA, MD, λ// and λ ⊥, were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T2-weighted images was observed. Conclusion High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI these normative data could potentially help in identifying pathology in diseased nerves.
AB - Purpose To implement high resolution diffusion tensor imaging (DTI) for visualization and quantification of peripheral nerves in human forearm. Materials and Methods This HIPAA-compliant study was approved by our Institutional Review Board and written informed consent was obtained from all the study participants. Images were acquired with T1-and T 2-weighted turbo spin echo with/without fat saturation, short tau inversion recovery (STIR). In addition, high spatial resolution (1.0×1.0×3.0 mm3) DTI sequence was optimized for clearly visualizing ulnar, superficial radial and median nerves in the forearm. Maps of the DTI derived indices, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (λ//) and radial diffusivity (λ⊥) were generated. Results For the first time, the three peripheral nerves, ulnar, superficial radial, and median, were visualized unequivocally on high resolution DTI-derived maps. DTI delineated the forearm nerves more clearly than other sequences. Significant differences in the DTI-derived measures, FA, MD, λ// and λ ⊥, were observed among the three nerves. A strong correlation between the nerve size derived from FA map and T2-weighted images was observed. Conclusion High spatial resolution DTI is superior in identifying and quantifying the median, ulnar, and superficial radial nerves in human forearm. Consistent visualization of small nerves and nerve branches is possible with high spatial resolution DTI these normative data could potentially help in identifying pathology in diseased nerves.
KW - diffusion tensor imaging
KW - fractional anisotropy
KW - human forearm
KW - mean diffusivity
KW - peripheral nerves
UR - http://www.scopus.com/inward/record.url?scp=84900015600&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84900015600&partnerID=8YFLogxK
U2 - 10.1002/jmri.24300
DO - 10.1002/jmri.24300
M3 - Article
C2 - 24243801
AN - SCOPUS:84900015600
SN - 1053-1807
VL - 39
SP - 1374
EP - 1383
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 6
ER -