Hand-Held Echocardiography by Advanced Practice Providers in Patients with Congestive Heart Failure

Maria Cecilia Tagle-Cornell, Barbara S. Novais, Songnan Wen, Justin N. Shipman, Deepa R. Mandale, Andrew P. Flom, Sandeep K. Sahnan, Lindsey M. Kriz, Michelle L. Alland, Christen W. Bird, Tasneem Z. Naqvi

Research output: Contribution to journalArticlepeer-review

Abstract

Objectives: The performed hand-held echocardiography (HHE) was evaluated and interpreted by trained advanced practice providers (APPs) on hospitalized CHF patients for image quality and interpretation by comparing with expert echocardiographer and SE findings. Background: Congestive heart failure (CHF) is associated with increased hospital admissions and mortality. While a standard echocardiogram (SE) is the gold standard for cardiac assessment, it is not readily available. Hospitalized CHF patients require rapid assessment for expedited treatment. Methods: Over 6 months, five trained APPs performed HHE on hospitalized CHF patients and interpreted: (a) left ventricular (LV) size, (b) LV ejection fraction (LVEF), and (c) right atrial pressure (RAP). The study echocardiographer reviewed and blindly interpreted the HHE images and compared them with APPs and SE findings. Kappa statistics determined the degree of agreement between APPs and the study echocardiographer’s interpretation of the HHE images and SE. Results: A total of 80 CHF patients (age 73 ± 14 years, 58% males; LVEF (by SE) 45 ± 19%; 36.3% body mass indexes ≥ 30 kg/m2) were enrolled. HHE interpretation by APPs had a good agreement for LVEF (kappa 0.79) with the study echocardiographer and SE (kappa 0.74) and a good agreement for RAP (kappa 0.67) with the study echocardiographer. The correlation between the absolute LVEF interpretation by the study echocardiographer on HHE and SE was r = 0.88 (p < 0.0001). Conclusions: Trained APPs obtained diagnostic-quality HHE images and interpreted the LV function and RAP in CHF patients in good agreement with the study echocardiographer. LVEF by HHE correlated with LVEF by SE. Our study suggests trained APPs can use HHE to evaluate LVEF and RAP in CHF patients, leading to expedited and optimized treatment.

Original languageEnglish (US)
Article number312
JournalJournal of Clinical Medicine
Volume13
Issue number2
DOIs
StatePublished - Jan 2024

Keywords

  • advanced practice providers
  • congestive heart failure
  • echocardiography
  • hand-held echocardiogram
  • heart failure
  • images

ASJC Scopus subject areas

  • General Medicine

Fingerprint

Dive into the research topics of 'Hand-Held Echocardiography by Advanced Practice Providers in Patients with Congestive Heart Failure'. Together they form a unique fingerprint.

Cite this