TY - JOUR
T1 - Evolution from physician-modified to company-manufactured fenestrated-branched endografts to treat pararenal and thoracoabdominal aortic aneurysms
AU - Oderich, Gustavo S.
AU - Ribeiro, Mauricio S.
AU - Sandri, Giuliano A.
AU - Tenorio, Emanuel R.
AU - Hofer, Janet M.
AU - Mendes, Bernardo C.
AU - Chini, Julia
AU - Cha, Stephen
N1 - Funding Information:
Author conflict of interest: G.S.O. has received consulting fees and grants from Cook Medical, W. L. Gore & Associates, and GE Healthcare (all paid to Mayo Clinic with no personal income). Author conflict of interest: G.S.O. has received consulting fees and grants from Cook Medical, W. L. Gore & Associates, and GE Healthcare (all paid to Mayo Clinic with no personal income). The editors and reviewers of this article have no relevant financial relationships to disclose per the JVS policy that requires reviewers to decline review of any manuscript for which they may have a conflict of interest.
Funding Information:
Author conflict of interest: G.S.O. has received consulting fees and grants from Cook Medical, W. L. Gore & Associates, and GE Healthcare (all paid to Mayo Clinic with no personal income).
Publisher Copyright:
© 2018 Society for Vascular Surgery
PY - 2019/7
Y1 - 2019/7
N2 - Objective: The purpose of this study was to review treatment trends and outcomes of patients who underwent fenestrated-branched endovascular aneurysm repair (F-BEVAR) of pararenal aneurysms (PRAs) or thoracoabdominal aortic aneurysms (TAAAs) using physician-modified endografts (PMEGs) or company-manufactured devices (CMDs). Methods: We reviewed the clinical data of 316 consecutive patients (242 male patients; mean age, 75 ± 8 years) who underwent F-BEVAR between 2007 and 2016. F-BEVAR was performed under two prospective investigational device exemption protocols since 2013. End points were mortality, major adverse events (MAEs), patient survival, reintervention, branch instability, aneurysm-related mortality, renal function deterioration, and target vessel patency. Results: There were 145 patients (46%) treated by PMEGs (84 PRAs, 26 extent IV and 35 extent I-III TAAAs) and 171 patients (54%) who had CMDs (88 PRAs, 42 extent IV and 41 extent I-III TAAAs). Choice of endograft evolved from PMEGs in 131 patients (83%) treated in the first half of experience to CMDs in 144 patients (91%) treated in the second half of experience (P < .001). Patients treated by PMEGs had significantly (P < .05) larger aneurysms, more chronic pulmonary and kidney disease, and higher comorbidity severity scores. A total of 1081 renal-mesenteric arteries were targeted in both groups. Technical success was lower for PMEGs (98% vs 99.5%; P = .02). Thirty-day mortality was 5.5% for PMEGs (PRAs, 1.2%; extent IV 3.8% and extent I-III, 17.1%) and 0% for CMDs (P = .0018). Patients treated by PMEGs had significantly more (P < .001) MAEs (48% vs 23%) and longer hospital stay (9 ± 10 days vs 6 ± 6 days; P = .001). Mean follow-up was significantly longer for patients treated by PMEGs (38 ± 26 months vs 14 ± 12 months; P < .001). At 3 years, patient survival (68% ± 4% vs 67% ± 8%; P = .11), freedom from reintervention (68% ± 4% vs 68% ± 8%; P = .17), primary (94% ± 2% vs 92% ± 2%; P = .64) and secondary target vessel patency (98% ± 1% vs 98% ± 1%; P = .89), and freedom from renal function deterioration (75% ± 4% vs 65% ± 6%; P = .24) were similar for patients treated by PMEGs or CMDs, respectively. Conclusions: Choice of F-BEVAR evolved from PMEGs to almost exclusively CMDs under physician-sponsored investigational device exemption protocols. PMEG patients had more comorbidities and larger aneurysms. CMDs were performed with higher technical success, no mortality, and fewer MAEs.
AB - Objective: The purpose of this study was to review treatment trends and outcomes of patients who underwent fenestrated-branched endovascular aneurysm repair (F-BEVAR) of pararenal aneurysms (PRAs) or thoracoabdominal aortic aneurysms (TAAAs) using physician-modified endografts (PMEGs) or company-manufactured devices (CMDs). Methods: We reviewed the clinical data of 316 consecutive patients (242 male patients; mean age, 75 ± 8 years) who underwent F-BEVAR between 2007 and 2016. F-BEVAR was performed under two prospective investigational device exemption protocols since 2013. End points were mortality, major adverse events (MAEs), patient survival, reintervention, branch instability, aneurysm-related mortality, renal function deterioration, and target vessel patency. Results: There were 145 patients (46%) treated by PMEGs (84 PRAs, 26 extent IV and 35 extent I-III TAAAs) and 171 patients (54%) who had CMDs (88 PRAs, 42 extent IV and 41 extent I-III TAAAs). Choice of endograft evolved from PMEGs in 131 patients (83%) treated in the first half of experience to CMDs in 144 patients (91%) treated in the second half of experience (P < .001). Patients treated by PMEGs had significantly (P < .05) larger aneurysms, more chronic pulmonary and kidney disease, and higher comorbidity severity scores. A total of 1081 renal-mesenteric arteries were targeted in both groups. Technical success was lower for PMEGs (98% vs 99.5%; P = .02). Thirty-day mortality was 5.5% for PMEGs (PRAs, 1.2%; extent IV 3.8% and extent I-III, 17.1%) and 0% for CMDs (P = .0018). Patients treated by PMEGs had significantly more (P < .001) MAEs (48% vs 23%) and longer hospital stay (9 ± 10 days vs 6 ± 6 days; P = .001). Mean follow-up was significantly longer for patients treated by PMEGs (38 ± 26 months vs 14 ± 12 months; P < .001). At 3 years, patient survival (68% ± 4% vs 67% ± 8%; P = .11), freedom from reintervention (68% ± 4% vs 68% ± 8%; P = .17), primary (94% ± 2% vs 92% ± 2%; P = .64) and secondary target vessel patency (98% ± 1% vs 98% ± 1%; P = .89), and freedom from renal function deterioration (75% ± 4% vs 65% ± 6%; P = .24) were similar for patients treated by PMEGs or CMDs, respectively. Conclusions: Choice of F-BEVAR evolved from PMEGs to almost exclusively CMDs under physician-sponsored investigational device exemption protocols. PMEG patients had more comorbidities and larger aneurysms. CMDs were performed with higher technical success, no mortality, and fewer MAEs.
KW - Company-manufactured device
KW - Fenestrated-branched endovascular aortic repair
KW - Physician-modified endografts
UR - http://www.scopus.com/inward/record.url?scp=85058697145&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85058697145&partnerID=8YFLogxK
U2 - 10.1016/j.jvs.2018.09.063
DO - 10.1016/j.jvs.2018.09.063
M3 - Article
C2 - 30583902
AN - SCOPUS:85058697145
SN - 0741-5214
VL - 70
SP - 31-42.e7
JO - Journal of vascular surgery
JF - Journal of vascular surgery
IS - 1
ER -