TY - JOUR
T1 - Diagnostic precision of ultrasonography in patients with Carpal Tunnel Syndrome
AU - Keleş, Işik
AU - Kendi, A. Tuba Karagülle
AU - Aydin, Gülümser
AU - Zöǧ, Ş Gülfer
AU - Orkun, Sevim
PY - 2005/6
Y1 - 2005/6
N2 - Objective: To evaluate the diagnostic value of ultrasonography in patients with electrophysiologically confirmed carpal tunnel syndrome. Design: A prospective ultrasonographic study of 35 wrists with electrophysiologically confirmed carpal tunnel syndrome and of 40 normal wrists. Receiver-operating- characteristics curves for the ultrasonographic measurements of median nerve were plotted to identify the most optimal cutoff values. Results: The ultrasonographic measurements of median nerves were found to be increased significantly in patients with carpal tunnel syndrome when compared with controls, particularly in terms of cross-sectional area (P < 0.001) and the bowing of the flexor retinaculum (P < 0.01) but not in the flattening ratio (P > 0.05). According to receiver-operating-characteristics curve results, the most optimal cutoff value for the cross-sectional area of the median nerve was obtained at the level of middle carpal tunnel, which was 9.3 mm2, with a sensitivity of 80% and specificity of 77.5%. The optimal cutoff value for the bowing of the flexor retinaculum was 3.7 mm, with a sensitivity of 71.4% and specificity of 55%, No optimum cutoff value could be identified from the receiver-operating-characteristics curves for the flattening ratio of median nerve. Conclusion: Ultrasonographic examination of the median nerve seems to be a promising method in the diagnosis of carpal tunnel syndrome, evaluating the morphologic changes of the median nerve in patients with clinical signs and symptoms. Further studies with wider series are needed to confirm our preliminary results.
AB - Objective: To evaluate the diagnostic value of ultrasonography in patients with electrophysiologically confirmed carpal tunnel syndrome. Design: A prospective ultrasonographic study of 35 wrists with electrophysiologically confirmed carpal tunnel syndrome and of 40 normal wrists. Receiver-operating- characteristics curves for the ultrasonographic measurements of median nerve were plotted to identify the most optimal cutoff values. Results: The ultrasonographic measurements of median nerves were found to be increased significantly in patients with carpal tunnel syndrome when compared with controls, particularly in terms of cross-sectional area (P < 0.001) and the bowing of the flexor retinaculum (P < 0.01) but not in the flattening ratio (P > 0.05). According to receiver-operating-characteristics curve results, the most optimal cutoff value for the cross-sectional area of the median nerve was obtained at the level of middle carpal tunnel, which was 9.3 mm2, with a sensitivity of 80% and specificity of 77.5%. The optimal cutoff value for the bowing of the flexor retinaculum was 3.7 mm, with a sensitivity of 71.4% and specificity of 55%, No optimum cutoff value could be identified from the receiver-operating-characteristics curves for the flattening ratio of median nerve. Conclusion: Ultrasonographic examination of the median nerve seems to be a promising method in the diagnosis of carpal tunnel syndrome, evaluating the morphologic changes of the median nerve in patients with clinical signs and symptoms. Further studies with wider series are needed to confirm our preliminary results.
KW - Carpal Tunnel Syndrome
KW - Electrodiagnosis
KW - Median Nerve
KW - Ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=18944403078&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=18944403078&partnerID=8YFLogxK
U2 - 10.1097/01.phm.0000163715.11645.96
DO - 10.1097/01.phm.0000163715.11645.96
M3 - Article
C2 - 15905658
AN - SCOPUS:18944403078
SN - 0894-9115
VL - 84
SP - 443
EP - 450
JO - American Journal of Physical Medicine and Rehabilitation
JF - American Journal of Physical Medicine and Rehabilitation
IS - 6
ER -