T1 - Diagnostic accuracy of cT enterography for active inflammatory terminal ileal Crohn disease
T2 - Comparison of full-dose and half-dose images reconstructed with FBP and half-dose images with SAFIRE1
AU - Gandhi, Namita S.
AU - Baker, Mark E.
AU - Goenka, Ajit H.
AU - Bullen, Jennifer A.
AU - Obuchowski, Nancy A.
AU - Remer, Erick M.
AU - Coppa, Christopher P.
AU - Einstein, David
AU - Feldman, Myra K.
AU - Kanmaniraja, Devaraju
AU - Purysko, Andrei S.
AU - Vahdat, Noushin
AU - Primak, Andrew N.
AU - Karim, Wadih
AU - Herts, Brian R.
N1 - Publisher Copyright:
© 2016 RSNA.
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2016/8
Y1 - 2016/8
N2 - Purpose: To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods: This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dualsource CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results: The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P <.003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P <.001). Conclusion: The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality.
AB - Purpose: To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods: This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dualsource CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results: The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P <.003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P <.001). Conclusion: The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality.
UR - http://www.scopus.com/inward/record.url?scp=84979916730&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84979916730&partnerID=8YFLogxK
U2 - 10.1148/radiol.2016151281
DO - 10.1148/radiol.2016151281
M3 - Article
C2 - 27077382
AN - SCOPUS:84979916730
SN - 0033-8419
VL - 280
SP - 436
EP - 445
JO - Radiology
JF - Radiology
IS - 2
ER -