Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry

Matheus Simonato, Brian K. Whisenant, Axel Unbehaun, Jörg Kempfert, Henrique B. Ribeiro, Ran Kornowski, Magdalena Erlebach, Sabine Bleiziffer, Stephan Windecker, Thomas Pilgrim, Daijiro Tomii, Mayra Guerrero, Yousif Ahmad, John K. Forrest, Matteo Montorfano, Marco Ancona, Matti Adam, Hendrik Wienemann, Ariel Finkelstein, Pedro VillablancaPablo Codner, David Hildick-Smith, Enrico Ferrari, Anna Sonia Petronio, Jasmin Shamekhi, Patrizia Presbitero, Giuseppe Bruschi, Tanja Rudolph, Alfredo Cerillo, David Attias, Mohammed Nejjari, Alexandre Abizaid, Maurício Felippi de Sá Marchi, Eric Horlick, Harindra Wijeysundera, Martin Andreas, Arun Thukkani, Marco Agrifoglio, Alessandro Iadanza, L. Matthew Baer, Michael G. Nanna, Danny Dvir

Research output: Contribution to journalArticlepeer-review

Abstract

Background: Mitral valve-in-valve (ViV) is associated with suboptimal hemodynamics and rare left ventricular outflow tract (LVOT) obstruction. Objectives: This study aimed to determine whether device position and asymmetry are associated with these outcomes. Methods: Patients undergoing SAPIEN 3 (Edwards Lifesciences) mitral ViV included in the VIVID (Valve-in-Valve International Data) Registry were studied. Clinical endpoints are reported according to Mitral Valve Academic Research Consortium definitions. Residual mitral valve stenosis was defined as mean gradient ≥5 mm Hg. Depth of implantation (percentage of transcatheter heart valve [THV] atrial to the bioprosthesis ring) and asymmetry (ratio of 2 measures of THV height) were evaluated. Results: A total of 222 patients meeting the criteria for optimal core lab evaluation were studied (age 74 ± 11.6 years; 61.9% female; STS score = 8.3 ± 7.1). Mean asymmetry was 6.2% ± 4.4%. Mean depth of implantation was 19.0% ± 10.3% atrial. Residual stenosis was common (50%; mean gradient 5.0 ± 2.6 mm Hg). LVOT obstruction occurred in 7 cases (3.2%). Implantation depth was not a predictor of residual stenosis (OR: 1.19 [95% CI: 0.92-1.55]; P = 0.184), but more atrial implantation was protective against LVOT obstruction (0.7% vs 7.1%; P = 0.009; per 10% atrial, OR: 0.48 [95% CI: 0.24-0.98]; P = 0.044). Asymmetry was found to be an independent predictor of residual stenosis (per 10% increase, OR: 2.30 [95% CI: 1.10-4.82]; P = 0.027). Conclusions: Valve stenosis is common after mitral ViV. Asymmetry was associated with residual stenosis. Depth of implantation on its own was not associated with residual stenosis but was associated with LVOT obstruction. Technical considerations to reduce postdeployment THV asymmetry should be considered.

Original languageEnglish (US)
Pages (from-to)2615-2627
Number of pages13
JournalJACC: Cardiovascular Interventions
Volume16
Issue number21
DOIs
StatePublished - Nov 13 2023

Keywords

  • SAPIEN 3
  • depth of implantation
  • left ventricular outflow tract obstruction
  • mitral valve-in-valve
  • positioning
  • residual stenosis

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Clinical and Hemodynamic Outcomes of Balloon-Expandable Mitral Valve-in-Valve Positioning and Asymmetric Deployment: The VIVID Registry'. Together they form a unique fingerprint.

Cite this