TY - JOUR
T1 - Are Serum Ion Levels Elevated in Pediatric Patients with Metal Implants?
AU - Mathew, Smitha E.
AU - Xie, Yong
AU - Bagheri, Leila
AU - Claton, Liam E.
AU - Chu, Lin
AU - Badreldin, Amr
AU - Abdel, Matthew P.
AU - Van Wijnen, Andre J.
AU - Haft, Geoffrey F.
AU - Milbrandt, Todd A.
AU - Larson, A. Noelle
N1 - Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/3/1
Y1 - 2022/3/1
N2 - Background: Previous studies report elevated serum titanium (Ti) levels in children with spinal implants. To provide additional data on this topic, we sought to assess serum ion levels at multiple timepoints in pediatric patients with growing spine devices, spinal fusion instrumentation, and extremity implants placed for fracture treatment. We hypothesized that serum Ti, cobalt (Co), and chromium (Cr) levels would be elevated in pediatric patients with growing spine devices compared with patients with extremity implants. Methods: Pediatric patients undergoing any primary spine implant placement, those with spine implant revision or removal surgery and patients with other appendicular implant removal had serum Ti, Co, and Cr ion levels drawn at the time of surgery. Fifty-one patients (12 growing spine devices, 13 fusions, and 26 extremity implants) had one set of labs, 31 of whom had labs drawn both preoperatively and postoperatively. Biopsies obtained from tissue specimens at the time of implant revision were analyzed histologically for the presence of metal debris and macrophage activity. Results: Patients with growing spine implants had elevated serum Ti (3.3 vs. 1.9 ng/mL, P=0.01) and Cr levels (1.2 vs. 0.27 ng/mL, P=0.01) in comparison to patients with fusion rods or extremity implants. With respect to patients with extremity implants, patients with growing spine devices had elevated serum Ti (3.3 vs. 0.98 ng/mL, P=0.013), Co (0.63 vs. 0.26 ng/mL, P=0.017), and Cr levels (1.18 vs. 0.26 ng/mL, P=0.005). On matched pairs analysis, patients who had labs drawn before and after spine implantation had significant increase in serum Ti levels (0.57 vs. 3.3 ng/mL, P=0.02). Histology of tissue biopsies adjacent to growing spine implants showed presence of metal debris and increased macrophage activity compared with patients with extremity implants. Conclusion: Serum Ti, Co, and Cr levels are elevated in children with spinal implants compared with those with extremity implants, particularly in those with growing spine devices. However, the clinical significance of these findings remains to be determined. Level of Evidence: Level II - prospective comparative study.
AB - Background: Previous studies report elevated serum titanium (Ti) levels in children with spinal implants. To provide additional data on this topic, we sought to assess serum ion levels at multiple timepoints in pediatric patients with growing spine devices, spinal fusion instrumentation, and extremity implants placed for fracture treatment. We hypothesized that serum Ti, cobalt (Co), and chromium (Cr) levels would be elevated in pediatric patients with growing spine devices compared with patients with extremity implants. Methods: Pediatric patients undergoing any primary spine implant placement, those with spine implant revision or removal surgery and patients with other appendicular implant removal had serum Ti, Co, and Cr ion levels drawn at the time of surgery. Fifty-one patients (12 growing spine devices, 13 fusions, and 26 extremity implants) had one set of labs, 31 of whom had labs drawn both preoperatively and postoperatively. Biopsies obtained from tissue specimens at the time of implant revision were analyzed histologically for the presence of metal debris and macrophage activity. Results: Patients with growing spine implants had elevated serum Ti (3.3 vs. 1.9 ng/mL, P=0.01) and Cr levels (1.2 vs. 0.27 ng/mL, P=0.01) in comparison to patients with fusion rods or extremity implants. With respect to patients with extremity implants, patients with growing spine devices had elevated serum Ti (3.3 vs. 0.98 ng/mL, P=0.013), Co (0.63 vs. 0.26 ng/mL, P=0.017), and Cr levels (1.18 vs. 0.26 ng/mL, P=0.005). On matched pairs analysis, patients who had labs drawn before and after spine implantation had significant increase in serum Ti levels (0.57 vs. 3.3 ng/mL, P=0.02). Histology of tissue biopsies adjacent to growing spine implants showed presence of metal debris and increased macrophage activity compared with patients with extremity implants. Conclusion: Serum Ti, Co, and Cr levels are elevated in children with spinal implants compared with those with extremity implants, particularly in those with growing spine devices. However, the clinical significance of these findings remains to be determined. Level of Evidence: Level II - prospective comparative study.
KW - adverse local tissue reactions
KW - chromium
KW - cobalt
KW - magnetic rods
KW - scoliosis
KW - stainless steel
KW - titanium
UR - http://www.scopus.com/inward/record.url?scp=85118154968&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85118154968&partnerID=8YFLogxK
U2 - 10.1097/BPO.0000000000001957
DO - 10.1097/BPO.0000000000001957
M3 - Article
C2 - 34619722
AN - SCOPUS:85118154968
SN - 0271-6798
VL - 42
SP - 162
EP - 168
JO - Journal of Pediatric Orthopaedics
JF - Journal of Pediatric Orthopaedics
IS - 3
ER -