Accelerating spiral deblurring with square kernels and low-pass preconditioning

Dinghui Wang, Tzu Cheng Chao, James G. Pipe

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: Robust implementation of spiral imaging requires efficient deblurring. A deblurring method was previously proposed to separate and deblur water and fat simultaneously, based on image-space kernel operations. The goal of this work is to improve the performance of the previous deblurring method using kernels with better properties. Methods: Four types of kernels were formed using different models for the region outside the collected k-space as well as low-pass preconditioning (LP). The performances of the kernels were tested and compared with both phantom and volunteer data. Data were also synthesized to evaluate the SNR. Results: The proposed “square” kernels are much more compact than the previously used circular kernels. Square kernels have better properties in terms of normalized RMS error, structural similarity index measure, and SNR. The square kernels created by LP demonstrated the best performance of artifact mitigation on phantom data. Conclusions: The sizes of the blurring kernels and thus the computational cost can be reduced by the proposed square kernels instead of the previous circular ones. Using LP may further enhance the performance.

Original languageEnglish (US)
Pages (from-to)1200-1208
Number of pages9
JournalMagnetic Resonance in Medicine
Volume91
Issue number3
DOIs
StatePublished - Mar 2024

Keywords

  • deblurring
  • off-resonance correction
  • spiral
  • water-fat imaging

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this