TY - JOUR
T1 - Using Enhanced Depth Imaging Optical Coherence Tomography-Derived Parameters to Discriminate between Eyes with and without Glaucoma
T2 - A Cross-Sectional Comparative Study
AU - Lopes, Flavio Siqueira Santos
AU - Matsubara, Igor
AU - Almeida, Izabela
AU - Gracitelli, Carolina Pelegrini Barbosa
AU - Dorairaj, Syril K.
AU - Vessani, Roberto Murad
AU - Paranhos, Augusto
AU - Prata, Tiago Santos
N1 - Funding Information:
3 European Glaucoma Society Terminology and Guidelines for Glaucoma, 4th Edition – Chapter 3: Treatment principles and options Supported by the EGS Foundation: Part 1: Foreword; Introduction; Glossary; Chapter 3 Treatment principles and options. Br J Oph-thalmol. 2017;101(6):130–95.
Publisher Copyright:
© 2020 S. Karger AG, Basel. All rights reserved.
PY - 2021/2
Y1 - 2021/2
N2 - Introduction: New technologies have been developed in order to decrease interpersonal influence and subjectivity during the glaucoma diagnosis process. Enhanced depth imaging spectral-domain OCT (EDI OCT) has turned up as a favorable tool for deep optic nerve head (ONH) structures assessment. Objective: A prospective cross-sectional study was conducted to compare the diagnostic performance of different EDI OCT-derived parameters to discriminate between eyes with and without glaucoma. Material and Methods: The following ONH parameters were measured: Lamina cribrosa (LC) thickness and area; prelaminar neural tissue (PLNT) thickness and area; average Bruch's membrane opening-minimum rim width (BMO-MRW), superior BMO-MRW, and inferior BMO-MRW. Peripapillary retinal nerve fiber layer (pRNFL) thickness was also obtained. Results: Seventy-three participants were included. There were no significant differences between AUCs for average BMO-MRW (0.995), PLNT area (0.968), and average pRNFL thickness (0.975; p ≥ 0.089). However, AUCs for each of these 3 parameters were significantly larger than LC area AUC (0.701; p ≤ 0.001). Sensitivities at 80% specificity were: PLNT area = 92.3%, average BMO-MRW = 97.4%, and average pRNFL thickness = 94.9%. Conclusions: Comparing the diagnostic performance of different EDI OCT ONH parameters to discriminate between eyes with and without glaucoma, we found better results for neural tissue-based indexes (BMO-MRW and PLNT area) compared to laminar parameters. In this specific population, these neural tissue-based parameters (including PLNT area, which was investigated by the first time in the present study) had a diagnostic performance comparable to that of the conventional pRNFL thickness protocol.
AB - Introduction: New technologies have been developed in order to decrease interpersonal influence and subjectivity during the glaucoma diagnosis process. Enhanced depth imaging spectral-domain OCT (EDI OCT) has turned up as a favorable tool for deep optic nerve head (ONH) structures assessment. Objective: A prospective cross-sectional study was conducted to compare the diagnostic performance of different EDI OCT-derived parameters to discriminate between eyes with and without glaucoma. Material and Methods: The following ONH parameters were measured: Lamina cribrosa (LC) thickness and area; prelaminar neural tissue (PLNT) thickness and area; average Bruch's membrane opening-minimum rim width (BMO-MRW), superior BMO-MRW, and inferior BMO-MRW. Peripapillary retinal nerve fiber layer (pRNFL) thickness was also obtained. Results: Seventy-three participants were included. There were no significant differences between AUCs for average BMO-MRW (0.995), PLNT area (0.968), and average pRNFL thickness (0.975; p ≥ 0.089). However, AUCs for each of these 3 parameters were significantly larger than LC area AUC (0.701; p ≤ 0.001). Sensitivities at 80% specificity were: PLNT area = 92.3%, average BMO-MRW = 97.4%, and average pRNFL thickness = 94.9%. Conclusions: Comparing the diagnostic performance of different EDI OCT ONH parameters to discriminate between eyes with and without glaucoma, we found better results for neural tissue-based indexes (BMO-MRW and PLNT area) compared to laminar parameters. In this specific population, these neural tissue-based parameters (including PLNT area, which was investigated by the first time in the present study) had a diagnostic performance comparable to that of the conventional pRNFL thickness protocol.
KW - Glaucoma
KW - Optic nerve diseases
KW - Optical coherence tomography
KW - Tomography
UR - http://www.scopus.com/inward/record.url?scp=85101680141&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85101680141&partnerID=8YFLogxK
U2 - 10.1159/000508952
DO - 10.1159/000508952
M3 - Article
C2 - 32454499
AN - SCOPUS:85101680141
SN - 0030-3747
VL - 64
SP - 108
EP - 115
JO - Ophthalmic Research
JF - Ophthalmic Research
IS - 1
ER -