TY - JOUR
T1 - Three-dimensional sonographic measurement of contralateral lung volume in fetuses with isolated congenital diaphragmatic hernia
AU - Ruano, Rodrigo
AU - Aubry, Marie Cécile
AU - Barthe, Bruno
AU - Dumez, Yves
AU - Zugaib, Marcelo
AU - Benachi, Alexandra
PY - 2008/6/1
Y1 - 2008/6/1
N2 - Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/e-ContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm3 and 1.11 cm3, respectively, with absolute limits of agreement ranging from -1.19 cm3 to +3.17 cm3. The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm3; range, 0.22-0.99 cm3) than in survival cases (median, 0.58 cm3; range, 0.42-0.92 cm3 [p < 0.01]). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose.
AB - Purpose. To use 3-dimensional sonography (3DUS) to measure contralateral lung volume and evaluate the potential of this measurement to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods. Between January 2002 and December 2004, the contralateral lung volumes of 39 fetuses with isolated CDH were measured via 3DUS using rotational multiplanar imaging. The observed/expected contralateral fetal lung volume ratios (o/e-ContFLVR) were compared with the lung/head ratio (LHR), observed/expected total fetal lung volume ratio (o/e-TotFLVR), and postnatal outcome. Results. Contralateral lung volumes are less reduced than total lung volumes in CDH. The bias and precision of 3DUS in estimating contralateral lung volumes were 0.99 cm3 and 1.11 cm3, respectively, with absolute limits of agreement ranging from -1.19 cm3 to +3.17 cm3. The o/e-ContFLVR was significantly lower in neonatal death cases (median, 0.49 cm3; range, 0.22-0.99 cm3) than in survival cases (median, 0.58 cm3; range, 0.42-0.92 cm3 [p < 0.01]). Overall accuracy of the o/e-ContFLVR, o/e-TotFLVR, and LHR in predicting neonatal death were 67.7% (21/31), 80.7% (25/31), and 77.4% (24/31), respectively. Conclusion. Although o/e-ContFLVR can be precisely measured with 3DUS and can be used to predict neonatal death in CDH, it is less accurate than LHR and o/e-TotFLVR for that purpose.
KW - 3-dimensional ultrasonography
KW - Congenital diaphragmatic hernia
KW - Fetal malformations
KW - Prenatal diagnosis
KW - Pulmonary hypoplasia
KW - Ultrasonography
UR - http://www.scopus.com/inward/record.url?scp=44349119904&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=44349119904&partnerID=8YFLogxK
U2 - 10.1002/jcu.20430
DO - 10.1002/jcu.20430
M3 - Article
C2 - 18067125
AN - SCOPUS:44349119904
SN - 0091-2751
VL - 36
SP - 273
EP - 278
JO - Journal of Clinical Ultrasound
JF - Journal of Clinical Ultrasound
IS - 5
ER -