T1 - Simulating scanner-and algorithm-specific 3D CT noise texture using physics-informed 2D and 2.5D generative neural network models
AU - Gong, Hao
AU - Huber, Thomas M.
AU - Winfree, Timothy
AU - Scott, Hsieh
AU - Yu, Lifeng
AU - Leng, Shuai
AU - McCollough, Cynthia H
N1 - Publisher Copyright:
© 2025 SPIE.
PY - 2025
Y1 - 2025
N2 - Low-dose CT simulation is needed to assess reconstruction/denoising techniques and optimize dose. Projection-domain noise-insertion methods require manufacturers' proprietary tools. Image-domain noise-insertion methods face various challenges that affect generalizability, and few have been systematically validated for 3D noise synthesis. To improve generalizability, we presented a physics-informed model-based generative neural network for simulating scanner- and algorithm-specific low-dose CT exams (PALETTE). PALETTE included a noise-prior-generation process, a Noise2Noisier sub-network, and a noise-texture-synthesis sub-network. Custom regularization terms were developed to enforce 3D noise texture quality. Using PALETTE, one 2D and two 2.5D models (denoted as 2.5D N-N and N-1) were developed to conduct 2D and effective 3D noise modeling, respectively (input/output images: 2D - 1/1, 2.5D N-N - 3/3, 2.5D N-1-5/1). These models were trained and tested with an open-access abdominal CT dataset, including 20 testing cases reconstructed with two kernels and various field-of-view. In visual inspection, the 2D and 2.5D N-N models generated realistic local and global noise texture, while 2.5D N-1 showed more perceptual difference using the sharper kernel and coronal reformat. In quantitative evaluation, local noise level was compared using mean-absolute-percent-difference (MAPD), and global spectral similarity was assessed using spectral correlation mapper (SCM) and spectral angle mapper (SAM). The 2D model provided equivalent or relatively better performance than 2.5D models, showing well-matched local noise levels and high spectral similarity compared to the reference (sharper/smoother kernels): MAPD - 2D 1.5%/5.6% (p>0.05), 2.5D N-N 8.5%/7.9% (p<0.05), 2.5D N-1 12.3%/10.9% (p<0.05); mean SCM - 2D 0.97/0.97, 2.5D N-N 0.96/0.97, 2.5D N-1 0.85/0.97; mean SAM - 2D 0.12/0.12, 2.5D N-N 0.14/0.12, 2.5D N-1 0.37/0.12. With tripled model width, the 2.5D N-N outperformed N-1. This indicated 2.5D models need more learning capacity to further enhance 3D noise modeling. Using physics-based prior information, PALETTE can provide high-quality low-dose CT simulation to resemble scanner- and algorithm-specific 3D noise characteristics.
AB - Low-dose CT simulation is needed to assess reconstruction/denoising techniques and optimize dose. Projection-domain noise-insertion methods require manufacturers' proprietary tools. Image-domain noise-insertion methods face various challenges that affect generalizability, and few have been systematically validated for 3D noise synthesis. To improve generalizability, we presented a physics-informed model-based generative neural network for simulating scanner- and algorithm-specific low-dose CT exams (PALETTE). PALETTE included a noise-prior-generation process, a Noise2Noisier sub-network, and a noise-texture-synthesis sub-network. Custom regularization terms were developed to enforce 3D noise texture quality. Using PALETTE, one 2D and two 2.5D models (denoted as 2.5D N-N and N-1) were developed to conduct 2D and effective 3D noise modeling, respectively (input/output images: 2D - 1/1, 2.5D N-N - 3/3, 2.5D N-1-5/1). These models were trained and tested with an open-access abdominal CT dataset, including 20 testing cases reconstructed with two kernels and various field-of-view. In visual inspection, the 2D and 2.5D N-N models generated realistic local and global noise texture, while 2.5D N-1 showed more perceptual difference using the sharper kernel and coronal reformat. In quantitative evaluation, local noise level was compared using mean-absolute-percent-difference (MAPD), and global spectral similarity was assessed using spectral correlation mapper (SCM) and spectral angle mapper (SAM). The 2D model provided equivalent or relatively better performance than 2.5D models, showing well-matched local noise levels and high spectral similarity compared to the reference (sharper/smoother kernels): MAPD - 2D 1.5%/5.6% (p>0.05), 2.5D N-N 8.5%/7.9% (p<0.05), 2.5D N-1 12.3%/10.9% (p<0.05); mean SCM - 2D 0.97/0.97, 2.5D N-N 0.96/0.97, 2.5D N-1 0.85/0.97; mean SAM - 2D 0.12/0.12, 2.5D N-N 0.14/0.12, 2.5D N-1 0.37/0.12. With tripled model width, the 2.5D N-N outperformed N-1. This indicated 2.5D models need more learning capacity to further enhance 3D noise modeling. Using physics-based prior information, PALETTE can provide high-quality low-dose CT simulation to resemble scanner- and algorithm-specific 3D noise characteristics.
KW - Deep learning
KW - diagnostic image quality assessment
KW - generative model
KW - low dose CT
KW - simulation
UR - https://www.scopus.com/pages/publications/105004576857
UR - https://www.scopus.com/pages/publications/105004576857#tab=citedBy
U2 - 10.1117/12.3047909
DO - 10.1117/12.3047909
M3 - Conference contribution
AN - SCOPUS:105004576857
T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE
BT - Medical Imaging 2025
A2 - Sabol, John M.
A2 - Li, Ke
A2 - Abbaszadeh, Shiva
PB - SPIE
T2 - Medical Imaging 2025: Physics of Medical Imaging
Y2 - 17 February 2025 through 21 February 2025
ER -