Task-based image quality assessment is essential for CT protocol and radiation dose optimization. Despite many ongoing efforts, there is still an unmet need to measure and monitor the quality of images acquired from each patient exam. In this work, we developed a patient-specific channelized Hotelling observer (CHO)-based method to estimate the lesion detectability for each individual patient scan. The ensemble of background was created from patient images to include both relatively uniform regions and anatomically varying regions. Signals were modelled from lesions of different sizes and contrast levels after incorporating the effect of contrast-dependent spatial resolution. Index of detectability (d') was estimated using a CHO framework. This method was applied to clinical patient images obtained from a CT scanner at 3 different radiation dose levels. The d' for 5 different lesion size/contrast conditions was calculated across the scan range of each patient exam. The average noise levels and the d' averaged from 5 conditions were 13.2/3.78, 17.1/2.93 and 21.9/2.43 at 100%, 50% and 25% dose levels, respectively.

Original languageEnglish (US)
Title of host publicationMedical Imaging 2025
Subtitle of host publicationPhysics of Medical Imaging
EditorsJohn M. Sabol, Ke Li, Shiva Abbaszadeh
PublisherSPIE
ISBN (Electronic)9781510685888
DOIs
StatePublished - 2025
EventMedical Imaging 2025: Physics of Medical Imaging - San Diego, United States
Duration: Feb 17 2025 → Feb 21 2025

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume13405
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2025: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego
Period2/17/25 → 2/21/25

Keywords

  • channelized Hotelling observer (CHO)
  • image quality assessment
  • lesion detectability
  • patient-specific

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Patient-specific Channelized Hotelling observer to estimate lesion detectability in CT'. Together they form a unique fingerprint.

Cite this