Skip to main navigation Skip to search Skip to main content

Local phase velocity imaging with wavenumber filter banks for ultrasound shear wave elastography

Research output: Contribution to journal › Article › peer-review

Abstract

Background and objectives: Ultrasound shear wave elastography is a non-invasive imaging technique for the assessment of the mechanical properties of tissues. However, existing techniques may yield erroneous assessments of lesion size or shape, particularly at low frequencies (250-500 Hz). Methods: This study introduces a novel imaging technique, Local Phase Velocity-based Imaging utilizing Wavenumber-domain Bell Filters (LPVI-WBF), which enables the imaging of shear wave velocity in soft tissue at a single low frequency. This approach offers enhanced tissue lateral propagation and more precise stiffness measurements at low frequencies. Operating in the frequency-wavenumber domain, LPVI-WBF employs an adaptive approach that utilizes a custom two-dimensional Fourier transform and its inverse to enhance the phase velocity image smoothness with reduced time complexity and memory usage. In comparison with the original Local Phase Velocity-Based Imaging (LPVI) method, the LPVI-WBF has been demonstrated to reduce bias in phase velocity values at low frequencies (250–500 Hz) for stiffer inclusions which are of considerable significance in clinical contexts. Furthermore, a sliding window is not employed in LPVI-WBF due to the associated complications. In this study, both left-to-right and right-to-left acoustic radiation force pushes are employed to enhance the outcomes of a single push. Results: The results of our experiments with a heterogeneous elastic phantom demonstrate that proposed LPVI-WBF is an effective technique for reconstructing two-dimensional shear wave phase velocity maps with more accurate values and a higher contrast-to-noise ratio between target and background at low frequencies (i.e., below 500 Hz). Moreover, it reduces the processing time and memory usage by 39% and 94%, respectively. Conclusion: This paper proposes a novel method for generating 2-D shear wave phase velocity images, resulting in local phase velocity maps that more accurately reflect the B-mode true shapes and values at low frequencies (i.e. below 500 Hz), as demonstrated by results obtained from inclusion phantoms. Additionally, LPVI-WBF provides a higher contrast-to-noise ratio (CNR) at low frequencies for stiffer inclusions, which are of great importance in clinical applications.

Original languageEnglish (US)
Article number108894
JournalComputer Methods and Programs in Biomedicine
Volume269
DOIs
StatePublished - Sep 2025

Keywords

  • Frequency-wavenumber domain
  • Local phase velocity-based imaging (LPVI)
  • Shear wave elastography (SWE)
  • Soft tissue
  • Ultrasound
  • k-space

ASJC Scopus subject areas

  • Software
  • Computer Science Applications
  • Health Informatics

Fingerprint

Dive into the research topics of 'Local phase velocity imaging with wavenumber filter banks for ultrasound shear wave elastography'. Together they form a unique fingerprint.

Cite this