TY - JOUR
T1 - Improved visualization of the wrist at lower radiation dose with photon-counting-detector CT
AU - Rajendran, Kishore
AU - Baffour, Francis
AU - Powell, Garret
AU - Glazebrook, Katrina
AU - Thorne, Jamison
AU - Larson, Nicholas
AU - Leng, Shuai
AU - McCollough, Cynthia
AU - Fletcher, Joel
N1 - Funding Information:
Research support for this work was provided, in part, to Mayo Clinic from Siemens Healthcare GmbH. The device described is a research scanner and is not commercially available.
Publisher Copyright:
© 2022, The Author(s), under exclusive licence to International Skeletal Society (ISS).
PY - 2023/1
Y1 - 2023/1
N2 - Objective: To compare the image quality of ultra-high-resolution wrist CTs acquired on photon-counting detector CT versus conventional energy-integrating-detector CT systems. Materials and methods: Participants were scanned on a photon-counting-detector CT system after clinical energy-integrating detector CTs. Energy-integrating-detector CT scan parameters: comb filter-based ultra-high-resolution mode, 120 kV, 250 mAs, Ur70 or Ur73 kernel, 0.4- or 0.6-mm section thickness. Photon-counting-detector CT scan parameters: non-comb-based ultra-high-resolution mode, 120 kV, 120 mAs, Br84 kernel, 0.4-mm section thickness. Two musculoskeletal radiologists blinded to CT system, scored specific osseous structures using a 5-point Likert scale (1 to 5). The Wilcoxon rank-sum test was used for statistical analysis of reader scores. Paired t-test was used to compare volume CT dose index, bone CT number, and image noise between CT systems. P-value < 0.05 was considered statistically significant. Results: Twelve wrists (mean participant age 55.3 ± 17.8, 6 females, 6 males) were included. The mean volume CT dose index was lower for photon-counting detector CT (9.6 ± 0.1 mGy versus 19.0 ± 6.7 mGy, p <.001). Photon-counting-detector CT images had higher Likert scores for visualization of osseous structures (median score = 4, p < 0.001). The mean bone CT number was higher in photon-counting-detector CT images (1946 ± 77 HU versus 1727 ± 49 HU, p < 0.001). Conversely, there was no difference in the mean image noise of the two CT systems (63 ± 6 HU versus 61 ± 6 HU, p = 0.13). Conclusion: Ultra-high-resolution imaging with photon-counting-detector CT depicted wrist structures more clearly than conventional energy-integrating-detector CT despite a 49% radiation dose reduction.
AB - Objective: To compare the image quality of ultra-high-resolution wrist CTs acquired on photon-counting detector CT versus conventional energy-integrating-detector CT systems. Materials and methods: Participants were scanned on a photon-counting-detector CT system after clinical energy-integrating detector CTs. Energy-integrating-detector CT scan parameters: comb filter-based ultra-high-resolution mode, 120 kV, 250 mAs, Ur70 or Ur73 kernel, 0.4- or 0.6-mm section thickness. Photon-counting-detector CT scan parameters: non-comb-based ultra-high-resolution mode, 120 kV, 120 mAs, Br84 kernel, 0.4-mm section thickness. Two musculoskeletal radiologists blinded to CT system, scored specific osseous structures using a 5-point Likert scale (1 to 5). The Wilcoxon rank-sum test was used for statistical analysis of reader scores. Paired t-test was used to compare volume CT dose index, bone CT number, and image noise between CT systems. P-value < 0.05 was considered statistically significant. Results: Twelve wrists (mean participant age 55.3 ± 17.8, 6 females, 6 males) were included. The mean volume CT dose index was lower for photon-counting detector CT (9.6 ± 0.1 mGy versus 19.0 ± 6.7 mGy, p <.001). Photon-counting-detector CT images had higher Likert scores for visualization of osseous structures (median score = 4, p < 0.001). The mean bone CT number was higher in photon-counting-detector CT images (1946 ± 77 HU versus 1727 ± 49 HU, p < 0.001). Conversely, there was no difference in the mean image noise of the two CT systems (63 ± 6 HU versus 61 ± 6 HU, p = 0.13). Conclusion: Ultra-high-resolution imaging with photon-counting-detector CT depicted wrist structures more clearly than conventional energy-integrating-detector CT despite a 49% radiation dose reduction.
KW - Photon-counting detector CT
KW - Radiation dosage
KW - Wrist
KW - X-ray computed tomography
UR - http://www.scopus.com/inward/record.url?scp=85134316609&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134316609&partnerID=8YFLogxK
U2 - 10.1007/s00256-022-04117-2
DO - 10.1007/s00256-022-04117-2
M3 - Article
C2 - 35831718
AN - SCOPUS:85134316609
SN - 0364-2348
VL - 52
SP - 23
EP - 29
JO - Skeletal Radiology
JF - Skeletal Radiology
IS - 1
ER -