TY - JOUR
T1 - Impact of radiocontrast use during left ventricular pacemaker lead implantation for cardiac resynchronization therapy
AU - Tester, Gregory A.
AU - Noheria, Amit
AU - Carrico, Heather L.
AU - Mears, Jennifer A.
AU - Cha, Yong Mei
AU - Powell, Brian D.
AU - Friedman, Paul A.
AU - Rea, Robert F.
AU - Hayes, David L.
AU - Asirvatham, Samuel J.
PY - 2012/2
Y1 - 2012/2
N2 - AimsThe risk of contrast-induced nephropathy (CIN) with radiocontrast use during left ventricular (LV) lead placement for cardiac resynchronization therapy (CRT) is unknown. It is unclear as to whether minimizing contrast use impacts adequacy of LV lead placement.Methods and resultsA retrospective analysis was performed of all LV leads placed for CRT at Mayo Clinic, Rochester, MN from 16 March 2001 to 1 April 2009. The primary goal was to assess risk of CIN and adequacy of lead placement depending on the amount of contrast administered during CRT placement. Contrast-induced nephropathy was defined as a <25 increase in serum creatinine <48 h post-procedurally. Adequacy of lead placement was assessed in a blinded fashion by review of procedural fluoroscopic and post-procedural radiographic images. Eight hundred and twenty-two subjects were divided based on the amount of procedural contrast used into tertile 1 (<55 mL, 257 patients), tertile 2 (5594 mL, 261 patients), and tertile 3 (<95 mL, 304 patients). Contrast-induced nephropathy occurred in 5.4 of patients in tertile 1, 5.4 in tertile 2 and 11.8 in tertile 3 (P 0.004). Among the tertiles, lead positioning was optimal in 95, 80 and 66, respectively (P < 0.0001). Fluoroscopic time was 34 ± 23, 42 ± 26, and 48 ± 30 min in tertiles 1, 2, and 3 (P < 0.0001). ConclusionRisk of CIN with CRT implantations was substantial. Increased volume of radiocontrast used for LV lead placement was associated with substantially increased risk of CIN. Minimal contrast use was associated with decreased procedural times without adverse impact on adequacy of lead placement.
AB - AimsThe risk of contrast-induced nephropathy (CIN) with radiocontrast use during left ventricular (LV) lead placement for cardiac resynchronization therapy (CRT) is unknown. It is unclear as to whether minimizing contrast use impacts adequacy of LV lead placement.Methods and resultsA retrospective analysis was performed of all LV leads placed for CRT at Mayo Clinic, Rochester, MN from 16 March 2001 to 1 April 2009. The primary goal was to assess risk of CIN and adequacy of lead placement depending on the amount of contrast administered during CRT placement. Contrast-induced nephropathy was defined as a <25 increase in serum creatinine <48 h post-procedurally. Adequacy of lead placement was assessed in a blinded fashion by review of procedural fluoroscopic and post-procedural radiographic images. Eight hundred and twenty-two subjects were divided based on the amount of procedural contrast used into tertile 1 (<55 mL, 257 patients), tertile 2 (5594 mL, 261 patients), and tertile 3 (<95 mL, 304 patients). Contrast-induced nephropathy occurred in 5.4 of patients in tertile 1, 5.4 in tertile 2 and 11.8 in tertile 3 (P 0.004). Among the tertiles, lead positioning was optimal in 95, 80 and 66, respectively (P < 0.0001). Fluoroscopic time was 34 ± 23, 42 ± 26, and 48 ± 30 min in tertiles 1, 2, and 3 (P < 0.0001). ConclusionRisk of CIN with CRT implantations was substantial. Increased volume of radiocontrast used for LV lead placement was associated with substantially increased risk of CIN. Minimal contrast use was associated with decreased procedural times without adverse impact on adequacy of lead placement.
KW - Cardiac resynchronization therapy (CRT)
KW - Contrast-induced nephropathy
KW - Device implantation
KW - LV lead
KW - Radiocontrast
UR - http://www.scopus.com/inward/record.url?scp=84856305041&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84856305041&partnerID=8YFLogxK
U2 - 10.1093/europace/eur282
DO - 10.1093/europace/eur282
M3 - Review article
C2 - 22024598
AN - SCOPUS:84856305041
SN - 1099-5129
VL - 14
SP - 243
EP - 248
JO - Europace
JF - Europace
IS - 2
ER -