TY - GEN
T1 - Evaluation of vibro-acoustography techniques to map absorbed dose distribution in irradiated phantoms
AU - Vieira, Silvio L.
AU - Kinnick, Randall R.
AU - Baggio, André L.
AU - Nicolucci, Patricia
AU - Fatemi, Mostafa
AU - Carneiro, Adilton O.
PY - 2009/1/1
Y1 - 2009/1/1
N2 - This work presents Vibro-acoustography (VA) as a tool to visualize absorbed dose distributions in a polymer gel dosimeter. VA uses the radiation force of focused ultrasound to vibrate a small region of the sample. Different modalities of VA were used to investigate the feasibility of this technique to evaluate dose distribution in irradiated 'MAGIC' polymer gel. A phantom was designed using this polymer with 2% w/w added glass microspheres having an average diameter range between 40-75 μm. The phantom was irradiated using conventional 10 MeV X-rays from a linear accelerator at a distance of 100 cm. An absorbed dose of 50 gray was delivered to the gel. To study the phenomena of dose distribution, continuous wave (CW), toneburst and multifrequency VA were applied to the phantom. Images were generated from the phase and magnitude of the emitted sound from the irradiated area. The comparative accuracy of the different VA results were validated using transverse relaxation rate (R2) image analysis by Magnetic Resonance Imaging (MRI) and a treatment planning system. A contour map of R2 was registered with the transverse CW images, obtained with the focal point on the top surface, and a good correlation was found between the images. The axial profile of irradiated inclusion from the toneburst VA image obtained with excitation frequency of 75 kHz showed the best accuracy compared to other VA modalities. The results show that VA imaging has potential to visualize dose distribution in a polymer gel dosimeter.
AB - This work presents Vibro-acoustography (VA) as a tool to visualize absorbed dose distributions in a polymer gel dosimeter. VA uses the radiation force of focused ultrasound to vibrate a small region of the sample. Different modalities of VA were used to investigate the feasibility of this technique to evaluate dose distribution in irradiated 'MAGIC' polymer gel. A phantom was designed using this polymer with 2% w/w added glass microspheres having an average diameter range between 40-75 μm. The phantom was irradiated using conventional 10 MeV X-rays from a linear accelerator at a distance of 100 cm. An absorbed dose of 50 gray was delivered to the gel. To study the phenomena of dose distribution, continuous wave (CW), toneburst and multifrequency VA were applied to the phantom. Images were generated from the phase and magnitude of the emitted sound from the irradiated area. The comparative accuracy of the different VA results were validated using transverse relaxation rate (R2) image analysis by Magnetic Resonance Imaging (MRI) and a treatment planning system. A contour map of R2 was registered with the transverse CW images, obtained with the focal point on the top surface, and a good correlation was found between the images. The axial profile of irradiated inclusion from the toneburst VA image obtained with excitation frequency of 75 kHz showed the best accuracy compared to other VA modalities. The results show that VA imaging has potential to visualize dose distribution in a polymer gel dosimeter.
UR - http://www.scopus.com/inward/record.url?scp=77950964785&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77950964785&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2009.5333608
DO - 10.1109/IEMBS.2009.5333608
M3 - Conference contribution
C2 - 19964244
AN - SCOPUS:77950964785
SN - 9781424432967
T3 - Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009
SP - 796
EP - 799
BT - Proceedings of the 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society
PB - IEEE Computer Society
T2 - 31st Annual International Conference of the IEEE Engineering in Medicine and Biology Society: Engineering the Future of Biomedicine, EMBC 2009
Y2 - 2 September 2009 through 6 September 2009
ER -