TY - JOUR
T1 - Defibrillator challenges for the new millennium
T2 - The marriage of device and patient - Making and maintaining a good match
AU - Friedman, Paul A.
AU - Glikson, Michael
AU - Stanton, Marshall S.
PY - 2000
Y1 - 2000
N2 - Although it has become clear that implantable cardioverter defibrillators (ICDs) are effective, important challenges remain for the physician. Due to the limitations of available risk stratification tools, patient selection for primary sudden death prevention remains controversial in many populations. Additionally, the proliferation of device choices has led to challenges in matching the appropriate device to the individual patient: device size is balanced against longevity; the advantages of dual chamber systems is weighed against their increased complexity; physician and patient preferences in device implant site are constrained by site-dependent effects on defibrillation effectiveness and lead failure rates; and special consideration must be given to the patient with a preexisting pacemaker. After ICD placement, determination of appropriate follow-up frequency and methodology to assess device function must be considered. This article will review patient selection, device implant site selection, device-device interactions, single versus dual chamber ICD selection, and follow-up.
AB - Although it has become clear that implantable cardioverter defibrillators (ICDs) are effective, important challenges remain for the physician. Due to the limitations of available risk stratification tools, patient selection for primary sudden death prevention remains controversial in many populations. Additionally, the proliferation of device choices has led to challenges in matching the appropriate device to the individual patient: device size is balanced against longevity; the advantages of dual chamber systems is weighed against their increased complexity; physician and patient preferences in device implant site are constrained by site-dependent effects on defibrillation effectiveness and lead failure rates; and special consideration must be given to the patient with a preexisting pacemaker. After ICD placement, determination of appropriate follow-up frequency and methodology to assess device function must be considered. This article will review patient selection, device implant site selection, device-device interactions, single versus dual chamber ICD selection, and follow-up.
KW - Defibrillator
KW - Device-device interaction
KW - Follow-up
KW - Implantation
KW - Indications
UR - http://www.scopus.com/inward/record.url?scp=0034047911&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034047911&partnerID=8YFLogxK
U2 - 10.1111/j.1540-8167.2000.tb00034.x
DO - 10.1111/j.1540-8167.2000.tb00034.x
M3 - Article
C2 - 10868745
AN - SCOPUS:0034047911
SN - 1045-3873
VL - 11
SP - 697
EP - 709
JO - Journal of cardiovascular electrophysiology
JF - Journal of cardiovascular electrophysiology
IS - 6
ER -