T1 - Cellular responses to flow diverters in a tissue-engineered aneurysm model
AU - Liu, Wenjing
AU - Dai, Daying
AU - Ding, Yong Hong
AU - Liu, Yang
AU - Temnyk, Kristen
AU - Shen, Tiffany W.
AU - Cardinal, Kristen O.Halloran
AU - Kallmes, David F.
AU - Kadirvel, Ramanathan
N1 - Funding Information:
Funding This work was supported by National Institutes of Health grant number NS076491.
Publisher Copyright:
© Author(s) (or their employer(s)) 2021. No commercial re-use. See rights and permissions. Published by BMJ.
PY - 2021/8/1
Y1 - 2021/8/1
N2 - Background Notwithstanding the widespread implementation of flow diverters (FDs) in the treatment of intracranial aneurysms, the exact mechanism of action of these devices remains elusive. We aimed to advance the understanding of cellular responses to FD implantation using a 3D tissue-engineered in vitro aneurysm model. Methods Aneurysm-like blood vessel mimics (aBVMs) were constructed by electrospinning polycaprolactone nanofibers onto desired aneurysm-like geometries. aBVMs were seeded with human aortic smooth muscle cells (SMCs) followed by human aortic endothelial cells (ECs). FDs were then deployed in the parent vessel of aBVMs covering the aneurysm neck and were cultivated for 7, 14, or 28 days (n=3 for each time point). The EC and SMC coverage in the neck was measured semi-quantitatively. Results At day 7, the device segment in contact with the parent vessel was partially endothelialized. Also, the majority of device struts, but not pores, at the parent vessel and neck interface were partially covered with ECs and SMCs, while device struts in the middle of the neck lacked cell coverage. At 14 days, histology verified a neointimal-like lining had formed, partially covering both the struts and pores in the center of the neck. At 28 days, the majority of the neck was covered with a translucent neointimal-like layer. A higher degree of cellular coverage was seen on the struts and pores at the neck at 28 days compared with both 7 and 14 days. Conclusion aBVMs can be a valuable alternative tool for evaluating the healing mechanisms of endovascular aneurysm devices.
AB - Background Notwithstanding the widespread implementation of flow diverters (FDs) in the treatment of intracranial aneurysms, the exact mechanism of action of these devices remains elusive. We aimed to advance the understanding of cellular responses to FD implantation using a 3D tissue-engineered in vitro aneurysm model. Methods Aneurysm-like blood vessel mimics (aBVMs) were constructed by electrospinning polycaprolactone nanofibers onto desired aneurysm-like geometries. aBVMs were seeded with human aortic smooth muscle cells (SMCs) followed by human aortic endothelial cells (ECs). FDs were then deployed in the parent vessel of aBVMs covering the aneurysm neck and were cultivated for 7, 14, or 28 days (n=3 for each time point). The EC and SMC coverage in the neck was measured semi-quantitatively. Results At day 7, the device segment in contact with the parent vessel was partially endothelialized. Also, the majority of device struts, but not pores, at the parent vessel and neck interface were partially covered with ECs and SMCs, while device struts in the middle of the neck lacked cell coverage. At 14 days, histology verified a neointimal-like lining had formed, partially covering both the struts and pores in the center of the neck. At 28 days, the majority of the neck was covered with a translucent neointimal-like layer. A higher degree of cellular coverage was seen on the struts and pores at the neck at 28 days compared with both 7 and 14 days. Conclusion aBVMs can be a valuable alternative tool for evaluating the healing mechanisms of endovascular aneurysm devices.
KW - aneurysm
KW - device
KW - flow diverter
UR - http://www.scopus.com/inward/record.url?scp=85095996177&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85095996177&partnerID=8YFLogxK
U2 - 10.1136/neurintsurg-2020-016593
DO - 10.1136/neurintsurg-2020-016593
M3 - Article
C2 - 33158994
AN - SCOPUS:85095996177
SN - 1759-8478
VL - 13
SP - 746
EP - 751
JO - Journal of neurointerventional surgery
JF - Journal of neurointerventional surgery
IS - 8
ER -