TY - JOUR
T1 - Cardiac Implantable Electronic Devices in Ebstein Anomaly
T2 - Management and Outcomes
AU - Tan, Nicholas Y.
AU - Amin, Mustapha
AU - Dearani, Joseph A.
AU - McLeod, Christopher J.
AU - Stephens, Elizabeth H.
AU - Cannon, Bryan C.
AU - Miranda, William R.
AU - Connolly, Heidi M.
AU - Egbe, Alexander
AU - Asirvatham, Samuel J.
AU - Madhavan, Malini
N1 - Funding Information:
Dr Tan received the 2020–2021 Wilton W. Webster Research Fellowship Award in Clinical Cardiac Catheter Ablation from Heart Rhythm Society. M. Madhavan receives research funding from Boston Scientific, Bristol-Myers Squibb (BMS)/Pfizer, and Convatec, Inc; she is on the steering committee of CERTITUDE Registry, Biotronik Inc. Dr Asirvatham receives speaking/honoraria from Abbott, Biosense Webster, Biotronik, Boston Scientific, Medtronic, and Zoll. The other authors report no conflicts.
Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/7/1
Y1 - 2022/7/1
N2 - Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P=0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
AB - Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P=0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
KW - Ebstein anomaly
KW - defibrillator
KW - pacemaker, artificial
KW - tricuspid valve
UR - http://www.scopus.com/inward/record.url?scp=85134854905&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85134854905&partnerID=8YFLogxK
U2 - 10.1161/CIRCEP.121.010744
DO - 10.1161/CIRCEP.121.010744
M3 - Review article
C2 - 35763435
AN - SCOPUS:85134854905
SN - 1941-3149
VL - 15
SP - E010744
JO - Circulation: Arrhythmia and Electrophysiology
JF - Circulation: Arrhythmia and Electrophysiology
IS - 7
ER -