TY - GEN
T1 - Automating Carotid Intima-Media Thickness Video Interpretation with Convolutional Neural Networks
AU - Shin, Jae Y.
AU - Tajbakhsh, Nima
AU - Hurst, R. Todd
AU - Kendall, Christopher B.
AU - Liang, Jianming
N1 - Publisher Copyright:
© 2016 IEEE.
Copyright:
Copyright 2017 Elsevier B.V., All rights reserved.
PY - 2016/12/9
Y1 - 2016/12/9
N2 - Cardiovascular disease (CVD) is the leading cause of mortality yet largely preventable, but the key to prevention is to identify at-risk individuals before adverse events. For predicting individual CVD risk, carotid intima-media thickness (CIMT), a noninvasive ultrasound method, has proven to be valuable, offering several advantages over CT coronary artery calcium score. However, each CIMT examination includes several ultrasound videos, and interpreting each of these CIMT videos involves three operations: (1) select three end-diastolic ultrasound frames (EUF) in the video, (2) localize a region of interest (ROI) in each selected frame, and (3) trace the lumen-intima interface and the media-adventitia interface in each ROI to measure CIMT. These operations are tedious, laborious, and time consuming, a serious limitation that hinders the widespread utilization of CIMT in clinical practice. To overcome this limitation, this paper presents a new system to automate CIMT video interpretation. Our extensive experiments demonstrate that the suggested system performs reliably. The reliable performance is attributable to our unified framework based on convolutional neural networks (CNNs) coupled with our informative image representation and effective post-processing of the CNN outputs, which are uniquely designed for each of the above three operations.
AB - Cardiovascular disease (CVD) is the leading cause of mortality yet largely preventable, but the key to prevention is to identify at-risk individuals before adverse events. For predicting individual CVD risk, carotid intima-media thickness (CIMT), a noninvasive ultrasound method, has proven to be valuable, offering several advantages over CT coronary artery calcium score. However, each CIMT examination includes several ultrasound videos, and interpreting each of these CIMT videos involves three operations: (1) select three end-diastolic ultrasound frames (EUF) in the video, (2) localize a region of interest (ROI) in each selected frame, and (3) trace the lumen-intima interface and the media-adventitia interface in each ROI to measure CIMT. These operations are tedious, laborious, and time consuming, a serious limitation that hinders the widespread utilization of CIMT in clinical practice. To overcome this limitation, this paper presents a new system to automate CIMT video interpretation. Our extensive experiments demonstrate that the suggested system performs reliably. The reliable performance is attributable to our unified framework based on convolutional neural networks (CNNs) coupled with our informative image representation and effective post-processing of the CNN outputs, which are uniquely designed for each of the above three operations.
UR - http://www.scopus.com/inward/record.url?scp=84986266392&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84986266392&partnerID=8YFLogxK
U2 - 10.1109/CVPR.2016.277
DO - 10.1109/CVPR.2016.277
M3 - Conference contribution
AN - SCOPUS:84986266392
T3 - Proceedings of the IEEE Computer Society Conference on Computer Vision and Pattern Recognition
SP - 2526
EP - 2535
BT - Proceedings - 29th IEEE Conference on Computer Vision and Pattern Recognition, CVPR 2016
PB - IEEE Computer Society
T2 - 29th IEEE Conference on Computer Vision and Pattern Recognition, CVPR 2016
Y2 - 26 June 2016 through 1 July 2016
ER -