Artifact reduction strategies for prosthetic heart valve CT imaging

  • Jesse Habets
  • , Petr Symersky
  • , Tim Leiner
  • , Bas A.J.M. De Mol
  • , Willem P.Th M. Mali
  • , Ricardo P.J. Budde

Research output: Contribution to journal › Article › peer-review

Abstract

MultisliceCTevaluation of prosthetic heart valves (PHV) is limited by PHV-related artifacts. We assessed the influence of different kV settings, a metal artifact reduction filter (MARF) and an iterative reconstruction algorithm (IR) on PHV-induced artifacts in an in vitromodel.AMedtronic-Hall tilting disc and St Jude bileafet PHVwere imaged using a 64-slice scanner with 100 kV/165 mAs, 120 kV/100 mAs, 140 kV/67 mAs at an equalCTDIvol. Imageswere reconstructed with (1) filtered back projection (FBP), (2) IR, (3)MARFand (4) MARF and IR. Hypo- and hyperdense artifacts volumes (mean mm3± SD) were quantified with 2 thresholds (B-50 and C175 Hounsfield Units). Image noise was measured and the presence of secondary artifacts was scored by 2 observers independently. Mean hypodense artifacts for the Medtronic-Hall/St Jude valve (FBP) were 966 ± 23/1,738 ± 21 at 100 kV, 610 ± 13/ 991 ± 12 at 120 kV, and 420 ± 9/634 ±9 at 140 kV. Compared to FBP, hypodense artifact reductions for IR were 9/8 %, 10/7 % and 12/6 % respectively, for MARF 92 %/84 %, 89/81 % and 86/77 % respectively; for MARF ? IR 94/85 %, 92/82 %, and 90/79 % respectively. Mean hyperdense artifacts for the Medtronic-Hall/St Jude valve were 5,530 ± 48/ 6,940 ± 70 at 100 kV, 5,120 ± 42/6,250 ± 53 at 120 kV, and 5,011 ± 52/6,000 ± 0 at 140 kV. Reductions for IR were 2/2 %, 2/3 % and 3/4 % respectively, for MARF were 9/30 %, 0/25 %, 5/22 % respectively, MARF ? IR 12/32 %, 4/27 % and 7/25 % respectively. Secondary artifacts were found in all MARF images. Image noise was reduced in the IR images. In vitro PHV-related artifacts can be reduced by increasing kV despite maintaining identical CTDIvol. Although MARF is more effective than IR, it induces secondary artifacts.

Original languageEnglish (US)
Pages (from-to)2099-2108
Number of pages10
JournalInternational Journal of Cardiovascular Imaging
Volume28
Issue number8
DOIs
StatePublished - Dec 2012

Keywords

  • Computed tomography
  • Iterative reconstruction
  • Metal artifact reduction
  • Prosthetic heart valve
  • Tube voltage

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Artifact reduction strategies for prosthetic heart valve CT imaging'. Together they form a unique fingerprint.

Cite this