Skip to main navigation Skip to search Skip to main content

Accurate and reproducible enumeration of T-, B-, and NK lymphocytes using the BD FACSLyric 10-color system: A multisite clinical evaluation

  • Imelda Omana-Zapata
  • , Caren Mutschmann
  • , John Schmitz
  • , Sarah Gibson
  • , Kevin Judge
  • , Monika Aruda Indig
  • , Beverly Lu
  • , Doreen Taufman
  • , Alan M. Sanfilippo
  • , Wendy Shallenberger
  • , Sharon Graminske
  • , Rachel McLean
  • , Rubal I. Hsen
  • , Nicole D’Empaire
  • , Kimberly Dean
  • , Maurice O’Gorman

Research output: Contribution to journal › Article › peer-review

Abstract

Clinical flow cytometry is a reliable methodology for whole blood cell phenotyping for different applications. The BD FACSLyric™ system comprises a flow cytometer available in different optical configurations, BD FACSuite™ Clinical software, and optional BD FACS™ Universal Loader. BD FACSuite Clinical software used with BD™ FC Beads and BD CS&T Beads enable universal setup for performance QC, instrument control, data acquisition/storage, online/offline data analysis, and instrument standardization. BD Biosciences sponsored the clinical evaluation of the BD FACSLyric 10-color configuration at seven clinical sites using delinked and de-identified blood specimens from HIV-infected and uninfected subjects to enumerate T-, B-, and NK-lymphocytes with the BD Multitest™ reagents (BD Multitest IMK kit and BD Multitest 6-color TBNK). Samples were analyzed on the BD FACSLyric system with BD FACSuite Clinical software, and on the BD FACSCanto™ II system with BD FACSCanto clinical software and BD FACS 7-Color Setup beads. For equivalency between methods, data (n = 362) were analyzed with Deming regression for absolute count and percentage of lymphocytes. Results gave R 2 0.98, with slope values 0.96, and slope ranges between 0.90–1.05. The percent (%) bias values were <10% for T- and NK cells and <15% for B- cells. The between-site (n = 4) total precision was tested for 5 days (2 runs/ day), and gave %coefficient of variation below 10% for absolute cell counts. The stability claims were confirmed (n = 186) for the two BD Multitest reagents. The reference intervals were re-established in male and female adults (n = 134). The analysis by gender showed statistically significant differences for CD3 + and CD4 + T-cell counts and %CD4. In summary, the BD FACSLyric and the BD FACSCanto II systems generated comparable measurements of T-, B-, and NK-cells using BD Multitest assays.

Original languageEnglish (US)
Article numbere0211207
JournalPloS one
Volume14
Issue number1
DOIs
StatePublished - Jan 2019

ASJC Scopus subject areas

  • General

Fingerprint

Dive into the research topics of 'Accurate and reproducible enumeration of T-, B-, and NK lymphocytes using the BD FACSLyric 10-color system: A multisite clinical evaluation'. Together they form a unique fingerprint.

Cite this